Estimation of errors in determining intrathoracic blood volume using the single transpulmonary thermal dilution technique in hypovolemic shock.

نویسندگان

  • Mahesh Nirmalan
  • Terrance M Willard
  • Dennis J Edwards
  • Rod A Little
  • Paul M Dark
چکیده

BACKGROUND The transpulmonary thermal dilution technique has been widely adopted for monitoring cardiac preload and extravascular lung water in critically ill patients. This method assumes intrathoracic blood volume (ITBV) to be a fixed proportion of global end-diastolic volume (GEDV). This study determines the relation between GEDV and ITBV under normovolemic and hypovolemic conditions and quantifies the errors in estimating ITBV. METHODS Nineteen pigs allocated to control (n = 9) and shock (n = 10) groups were studied. Shock was maintained for 60 min followed by volume resuscitation. The dual dye-thermal dilution technique was used to measure GEDV and ITBV (ITBVm) at baseline (time 0), shock phase (30 and 90 min), and after resuscitation (150 min). The regression equations estimated from paired GEDV and ITBVm measurements under normovolemic and hypovolemic conditions were used to estimate ITBV from the corresponding GEDV, and the estimation errors were quantified. A more simplified equation, used in a commercially available clinical monitor (ITBV = 1.25 x GEDV), was then used to estimate ITBV. RESULTS The regression equation in the control group was ITBVm = 1.21 x GEDV + 99 (r = 0.89, P < 0.0001) and in the shock group at 30 and 90 min was ITBVm = 1.45 x GEDV + 0.6 (r = 0.95, P < 0.0001). The 95% confidence interval for the y-intercept was relatively wide, ranging from 31 to 168 and -47 to 49, respectively, for the two equations. The equation estimated in the control group led to overestimation of ITBV and a significant (P < 0.05) increase in errors in the shock group at 30 and 90 min. Errors in estimating ITBV using the simplified commercial algorithm were less than 15% under normovolemic and hypovolemic conditions. CONCLUSIONS The linear relation between GEDV and ITBV is maintained in hypovolemic shock. Even though the relation between GEDV and ITBV is influenced by circulatory volume and cardiac output, the mean errors in predicting ITBV were small and within clinically tolerable limits.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preload index: pulmonary artery occlusion pressure versus intrathoracic blood volume monitoring during lung transplantation.

UNLABELLED In this study, during lung transplantation, we analyzed a conventional preload index, the pulmonary artery occlusion pressure (PAOP), and a new preload index, the intrathoracic blood volume index (ITBVI), derived from the single-indicator transpulmonary dilution technique (PiCCO System), with respect to stroke volume index (SVIpa). We also evaluated the relationships between changes ...

متن کامل

Systemic Capillary Leak Syndrome associated with hypovolemic shock and compartment syndrome. Use of transpulmonary thermodilution technique for volume management

Systemic Capillary Leak Syndrome (SCLS) is a rare disorder characterized by increased capillary hyperpermeability leading to hypovolemic shock due to a markedly increased shift of fluid and protein from the intravascular to the interstitial space. Hemoconcentration, hypoalbuminemia and a monoclonal gammopathy are characteristic laboratory findings. Here we present a patient who suffered from SC...

متن کامل

Assessment of cardiac output with transpulmonary thermodilution during exercise in humans.

The accuracy and reproducibility of transpulmonary thermodilution (TPTd) to assess cardiac output (Q̇) in exercising men was determined using indocyanine green (ICG) dilution as a reference method. TPTd has been utilized for the assessment of Q̇ and preload indexes of global end-diastolic volume and intrathoracic blood volume, as well as extravascular lung water (EVLW) in resting humans. It remai...

متن کامل

Does the optimization of cardiac output by fluid loading increase splanchnic blood flow?

We studied the effects of increasing cardiac output by fluid loading on splanchnic blood flow in patients with haemodynamically stabilized septic shock. Eight patients (five female, 39-86 yr) were assessed using a transpulmonary thermo-dye-dilution technique for the measurement of cardiac index (CI) intrathoracic blood volume (ITBV) as a marker of cardiac preload and total blood volume (TBV). S...

متن کامل

Hemodynamic monitoring by double indicator dilution technique in patients after orthotopic heart transplantation

STUDY OBJECTIVES A transpulmonary thermal-dye dilution (TDD) technique using cold indocyanine green dye was utilized to monitor cardiac index (CI) and preload in patients after heart transplantation. Preload, determined by intrathoracic blood volume index (ITBVI) and global end-diastolic volume index (GEDVI), was compared to central venous pressure (CVP) and pulmonary artery occlusion pressure ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 103 4  شماره 

صفحات  -

تاریخ انتشار 2005