Infarct tissue heterogeneity assessed with contrast-enhanced MRI predicts spontaneous ventricular arrhythmia in patients with ischemic cardiomyopathy and implantable cardioverter-defibrillator.
نویسندگان
چکیده
BACKGROUND The relation between infarct tissue heterogeneity on contrast-enhanced MRI and the occurrence of spontaneous ventricular arrhythmia (or sudden cardiac death) is unknown. Therefore, the study purpose was to evaluate the predictive value of infarct tissue heterogeneity assessed with contrast-enhanced MRI on the occurrence of spontaneous ventricular arrhythmia with subsequent implantable cardioverter-defibrillator (ICD) therapy (as surrogate of sudden cardiac death) in patients with previous myocardial infarction. METHODS AND RESULTS Ninety-one patients (age, 65+/-11 years) with previous myocardial infarction scheduled for ICD implantation underwent cine MRI to evaluate left ventricular function and volumes and contrast-enhanced MRI for characterization of scar tissue (infarct gray zone as measure of infarct tissue heterogeneity, infarct core, and total infarct size). Appropriate ICD therapy was documented in 18 patients (20%) during a median follow-up of 8.5 months (interquartile range, 2.1 to 20.3). Multivariable Cox proportional hazards analysis revealed that infarct gray zone was the strongest predictor of the occurrence of spontaneous ventricular arrhythmia with subsequent ICD therapy (hazard ratio, 1.49/10 g; CI, 1.01 to 2.20; chi(2)=4.0; P=0.04). CONCLUSIONS Infarct tissue heterogeneity on contrast-enhanced MRI is the strongest predictor of spontaneous ventricular arrhythmia with subsequent ICD therapy (as surrogate of sudden cardiac death) among other clinical and MRI variables, that is, total infarct size and left ventricular function and volumes, in patients with previous myocardial infarction.
منابع مشابه
Myocardial scar extent evaluated by cardiac magnetic resonance imaging in ICD patients: differences between polymorphic and monomorphic spontaneous events during follow-up
Background Patients with ischemic cardiomyopathy have an increased risk for ventricular arrhythmia, since myocardial infarction can be the substrate for re-entrant arrhythmias. Contrast-enhanced cardiac magnetic resonance imaging (CMR) has proven to reliably quantify myocardial infarction. Aim of our study was to evaluate correlations between functional and contrast-enhanced CMR findings and sp...
متن کاملInfarct tissue heterogeneity by magnetic resonance imaging identifies enhanced cardiac arrhythmia susceptibility in patients with left ventricular dysfunction.
BACKGROUND The extent of the peri-infarct zone by magnetic resonance imaging (MRI) has been related to all-cause mortality in patients with coronary artery disease. This relationship may result from arrhythmogenesis in the infarct border. However, the relationship between tissue heterogeneity in the infarct periphery and arrhythmic substrate has not been investigated. In the present study, we q...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملCMR measurements of myocardial infarct heterogeneity using MCLE and IR-FGRE: correlation with arrhythmia inducibility and severe ICD events in patients with ischemic heart disease
Background In addition to measures of left ventricular ejection fraction (LVEF) and clinical staging of heart failure, myocardial infarct (MI) heterogeneity including MI and periinfarct gray-zone (GZ) has the potential to predict the occurrence of inducible sustained ventricular arrhythmia (VA) and spontaneous VA events after implantation of implantable defibrillator (ICD) in patients with isch...
متن کاملA randomized study of cardiac resynchronization therapy defibrillator versus dual-chamber implantable cardioverter-defibrillator in ischemic cardiomyopathy with narrow QRS: the NARROW-CRT study.
BACKGROUND Current recommendations require a QRS duration of ≥120 ms as a condition for prescribing cardiac resynchronization therapy (CRT). This study was designed to test the hypothesis that patients with heart failure (HF) of ischemic origin, current indications for defibrillator implantation, and QRS <120 ms may benefit from CRT in the presence of marked mechanical dyssynchrony. METHODS A...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular imaging
دوره 2 3 شماره
صفحات -
تاریخ انتشار 2009