An accurate and portable solid state neutron rem meter

نویسنده

  • T. M. Oakes
چکیده

Accurately resolving the ambient neutron dose equivalent spanning the thermal to 15 MeV energy range with a single configuration and lightweight instrument is desirable. This paper presents the design of a portable, high intrinsic efficiency, and accurate neutron rem meter whose energy-dependent response is electronically adjusted to a chosen neutron dose equivalent standard. The instrument may be classified as a moderating type neutron spectrometer, based on an adaptation to the classical Bonner sphere and position sensitive long counter, which, simultaneously counts thermalized neutrons by high thermal efficiency solid state neutron detectors. The use of multiple detectors and moderator arranged along an axis of symmetry (e.g., long axis of a cylinder) with known neutron-slowing properties allows for the construction of a linear combination of responses that approximate the ambient neutron dose equivalent. Variations on the detector configuration are investigated via Monte Carlo N-Particle simulations to minimize the total instrument mass while maintaining acceptable response accuracy—a dose error less than 15% for bare Cf, bare AmBe, an epi-thermal and mixed monoenergetic sources is found at less than 4.5 kg moderator mass in all studied cases. A comparison of the energy dependent dose equivalent response and resultant energy dependent dose equivalent error of the present dosimeter to commerciallyavailable portable rem meters and the prior art are presented. Finally, the present design is assessed by comparison of the simulated output resulting from applications of several known neutron sources and

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of a portable solid-state hemoglobinometer.

The most widely used and accepted method for hemoglobin determination is the cyanmethemoglobin method. However, laboratory spectrophotometers used with this procedure are not amenable to field use. We describe the design of a portable hemoglobinometer for use with the cyanmethemoglobin method. Solid-state light sources and detectors are used, and a simple meter readout of hemoglobin is produced...

متن کامل

Development of a light-weight portable neutron survey meter.

A light-weight portable neutron survey meter was developed using a mixed organic gas counter for dose management at nuclear power plants and accelerator facilities. This survey meter, NSN31041, is ~2 kg in weight and W160×H250×L300 mm(3) in size, which is capable of measuring neutron ambient dose equivalent rate from thermal to 15 MeV neutrons. The neutron energy response of the survey meter is...

متن کامل

The comparison between simple and advanced shielding materials for the shield of portable neutron sources

Background: Monte Carlo simulations play a vital role in the calculation of the necessary shielding both for neutrons and photons. Advanced and simple shielding materials against neutron and gamma rays were compared by simulation using the MCNB4B Monte Carlo code. The simulations were carried out for the three common neutron sources, namely the 252Cf, the 241Am/Be and the DD neutron generator w...

متن کامل

Development and test of a GEM-based TEPC for neutron protection dosimetry.

A novel tissue-equivalent proportional counter (TEPC) based on a gas electron multiplier (GEM) for measuring H*(10) for neutrons was designed and constructed. The pulse height spectra (PHS) of two different neutron sources (a 252Cf source and a AmBe source) were measured using the new TEPC. The measurements were made with the TEPC filled with two different gases (10P gas and a propane-based tis...

متن کامل

Design and simulation of a GEM-based TEPC as a neutron REM meter.

A new plate-like tissue equivalent proportional counter (TEPC) based on the gas electron multiplier (GEM) is being developed for use as a neutron rem meter. The advantage of a plate-like TEPC over a conventional spherical TEPC is that several of the plate-like TEPCs can be stacked together as one unit to increase sensitivity to neutrons. A GEM-based TEPC consists of four layers of materials in ...

متن کامل