Monte Carlo Study of Fetal Dosimetry Parameters for 6 MV Photon Beam
نویسندگان
چکیده
Because of the adverse effects of ionizing radiation on fetuses, prior to radiotherapy of pregnant patients, fetal dose should be estimated. Fetal dose has been studied by several authors in different depths in phantoms with various abdomen thicknesses (ATs). In this study, the effect of maternal AT and depth in fetal dosimetry was investigated, using peripheral dose (PD) distribution evaluations. A BEAMnrc model of Oncor linac using out of beam components was used for dose calculations in out of field border. A 6 MV photon beam was used to irradiate a chest phantom. Measurements were done using EBT2 radiochromic film in a RW3 phantom as abdomen. The followings were measured for different ATs: Depth PD profiles at two distances from the field's edge, and in-plane PD profiles at two depths. The results of this study show that PD is depth dependent near the field's edge. The increase in AT does not change PD depth of maximum and its distribution as a function of distance from the field's edge. It is concluded that estimating the maximum fetal dose, using a flat phantom, i.e., without taking into account the AT, is possible. Furthermore, an in-plane profile measured at any depth can represent the dose variation as a function of distance. However, in order to estimate the maximum PD the depth of D max in out of field should be used for in-plane profile measurement.
منابع مشابه
The dosimetry assessment of Varian Linear Accelerators of 6, 15 and 20 MV by Monte Carlo Method
Introduction: Monte Carlo method is often applied in radiation therapy as utilized in all the branches of science. An important requirement for successful radiotherapy is carefully examine the dose distribution specifications and decrease the difference between these features with experience to an acceptable level. In this study, the characteristics of 6, 15 and 20 MeV incident x-rays are prov...
متن کاملMonte carlo simulation of varian clinac iX 10 MV photon beam for small field dosimetry
Background: The lack of lateral electronic disequilibrium (LED) becomes a main problem in small field. This factor affects the dose in target volume cannot predict correctly. In addition, utilization of high-energy linear accelerator (10 MV) can emit some unwanted particles (electron contamination). Therefore, the aim of this study was to characterize head linear accelerator (linac) Varian Clin...
متن کاملBenchmarking of Monte Carlo model of 6 Mv photon beam produced by Siemens Oncor® linear accelerator: determination of initial electron beam parameters in comparison with measurement
Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator. Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by...
متن کاملA Monte Carlo simulation and dosimetric verification of physical wedges used in radiation therapy
Background: The presence of a wedge filter in the beam trajectory can modify the beam quality and cause some changes in the dosimetry parameters which are usually difficult to be measured directly and accurately. Material and Methods: In this study the MCNP-4C Monte Carlo code was used to simulate the 9 MV photon beam generated by a linear accelerator. Upon getting a good agreement bet...
متن کاملEstimation of Dosimetric Parameters based on KNR and KNCSF Correction Factors for Small Field Radiation Therapy at 6 and 18 MV Linac Energies using Monte Carlo Simulation Methods
Background: Estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. Hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at differen...
متن کامل