Using photoplethysmography in heart rate monitoring of patients with epilepsy.

نویسندگان

  • Judith van Andel
  • Constantin Ungureanu
  • Ronald Aarts
  • Frans Leijten
  • Johan Arends
چکیده

Heart rate is a useful neurophysiological sign when monitoring seizures in patients with epilepsy. In an ambulatory setting, heart rate is measured with ECG involving electrodes on the skin. This method is uncomfortable which is burdensome for patients and is sensitive to motion artifacts, which decrease the usability of measurements. In this study, green light photoplethysmography, an optical technique arising from the fitness industry, was evaluated for usefulness in a medical setting. Simultaneous overnight measurements of HR with a commercially available optical heart rate (OHR) sensor and with ECG (HRECG) were performed in 7 patients with epilepsy. Overall, there was no significant difference between OHR and HRECG in random 10-minute periods during wakefulness (p=0.69) and sleep (p=1.00). The Bland-Altman analysis showed negligible mean differences. Limits of agreement were higher during wakefulness and during the occurrence of two seizures possibly because of less reliable HRECG measurements due to motion artifacts. Optical heart rate seems less sensitive to these motion artifacts, and measurements are more user-friendly. The optical heart rate sensor may fill the gap of systems for ambulatory heart rate monitoring and can be especially useful in the context of seizure detection in patients with epilepsy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated Epileptic Seizure Detection Based on Wearable ECG and PPG in a Hospital Environment

Electrocardiography has added value to automatically detect seizures in temporal lobe epilepsy (TLE) patients. The wired hospital system is not suited for a long-term seizure detection system at home. To address this need, the performance of two wearable devices, based on electrocardiography (ECG) and photoplethysmography (PPG), are compared with hospital ECG using an existing seizure detection...

متن کامل

Lightweight wrist photoplethysmography for heavy exercise: motion robust heart rate monitoring algorithm

The challenge of heart rate monitoring based on wrist photoplethysmography (PPG) during heavy exercise is addressed. PPG is susceptible to motion artefacts, which have to be mitigated for accurate heart rate estimation. Motion artefacts are particularly apparent for wrist devices, for example, a smart watch, because of the high mobility of the arms. Proposed is a low complexity highly accurate ...

متن کامل

Validation of photoplethysmography as a method to detect heart rate during rest and exercise.

Despite their enhanced marketplace visibility, validity of wearable photoplethysmographic heart rate monitoring is scarce. Forty-seven healthy participants performed seven, 6-min exercise bouts and completed a valid skin type scale. Participants wore an Omron HR500U (OHR) and a Mio Alpha (MA), two commercial wearable photoplethysmographic heart rate monitors. Data were compared to a Polar RS800...

متن کامل

Effect of Exercise Training on Heart Rate Variability in Patients with Heart Failure After Percutaneous Coronary Intervention

Background: This study aims to evaluate the effect of exercise training on heart rate variability (HRV) and to determine the correlation between parameters of HRV and the ejection fraction in patients with heart failure after percutaneous coronary intervention.Material and Methods: Fifty patients with left ventricular ejection fraction ≤ 40% undergone percutaneous coronary intervention were r...

متن کامل

Hybrid optical imaging technology for long-term remote monitoring of skin perfusion and temperature behavior.

Photoplethysmography imaging (PPGI) and infrared thermography imaging (IRTI) are contactless camera-based measurement methods for monitoring a wide range of basic vital parameters. In particular, PPGI enhances the classical contact-based photoplethysmography. Approved evaluation algorithms of the well-established PPG method can easily be adapted for detection of heart rate, heart rate variabili...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Epilepsy & behavior : E&B

دوره 45  شماره 

صفحات  -

تاریخ انتشار 2015