The application of supercritical fluid extraction to cocaine and its metabolites in blood and urine.

نویسندگان

  • D L Allen
  • J S Oliver
چکیده

Supercritical fluid extraction (SFE) is emerging as a valuable analytical technique for use as an alternative to conventional solid-phase (SPE) and liquid-liquid extraction techniques. It is a relatively new technique based on the use of supercritical fluids for the isolation of analytes from various matrices and is attracting great interest because of the increasing need for a simple, rapid, environmentally friendly, automated, and selective extraction method. A new method using SFE procedures for the extraction of cocaine and its major metabolites, benzoylecgonine and ecgonine methyl ester, from whole blood and urine was developed. This study has shown that cocaine and its metabolites can be successfully extracted from blood and urine using SFE techniques. Levels measured using SFE have shown analyte recovery better than 70% for cocaine, better than 40% for benzoylecgonine, and better than 85% for ecognine methyl ester from whole blood and urine. Good run-to-run reproducibility was observed between each extraction with limits of detection and quantitation of 1 ng and 10 ng based on 200 microL of blood and urine. A comparison between SPE and developed SFE techniques was investigated to observe if a correlation existed between the two methods. Studies proved that a correlation did exist between the two methods for spiked blood and urine samples with comparative results. This paper details a procedure for the extraction of cocaine and its metabolites from blood and urine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Silent Cocaine Poisoning

Background: Cocaine poisoning is known for causing severe clinical effects such as tachycardia, hypertension, agitation and confusion. Absence of clinical manifestations in cocaine poisoning is unusual. Case report: A 26-year old man, known to be a cocaine addict, declared that he was forced by cocaine dealers to swallow many tablets of cocaine, six hours prior to admission to emergency departm...

متن کامل

An Environmental Friendly Process for Extraction of Active Constituents from Herbal Plants

Conventional methods for extraction of the active constituents from herbal plants, in addition to their high processing costs, are harmful to the environment owing to their time and energy consumption, uncontrollable parameters, use of toxic and dangerous solvents, loss of the extract, thermal instability, the contamination of the product with organic solvents and the loss of water-soluble comp...

متن کامل

Hydrothermal synthesis nanoparticle bysupercritical fluid

Supercritical fluid (SCF) technology has become an important tool of materials processing in the lasttwo decades. Supercritical CO2 and H2O are extensively being used in the preparation of a great variety ofnanomaterials. The greatest requirement in the application of nanomaterials is its size and morphology control, which determine the application potential of the nanoparticles, as...

متن کامل

Sub and Supercritical Decontamination of Oil-Based Drill Cuttings: A Review

Drill mud is a fluid which is used in oil extraction industries in order to cool and lubricate the drill bit. Due to containing numerous toxic components, it is considered as a hazardous waste which must be treated before discharging to the environment. Current separation techniques for drill cutting treatment can be categorized into three main categories of physical (dewatering), physiochemica...

متن کامل

Response surface methodology for optimization of supercritical fluid extraction of orange peel essential oil

Background: Orange peel essential oils were obtained using supercritical fluid extraction. This method is an important high scaling extraction methods that used for extraction of plant and animal extracts. Methodology: The experimental parameters of SFE such as temperature, pressure, and extraction time and modifier volume were optimized using a central composite design after a 24-1fractional ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 24 3  شماره 

صفحات  -

تاریخ انتشار 2000