Two-dimensional capillary electrophoresis: capillary isoelectric focusing and capillary zone electrophoresis with laser-induced fluorescence detection.

نویسندگان

  • Jane A Dickerson
  • Lauren M Ramsay
  • Oluwatosin O Dada
  • Nathan Cermak
  • Norman J Dovichi
چکیده

CIEF and CZE are coupled with LIF detection to create an ultrasensitive 2-D separation method for proteins. In this method, two capillaries are joined through a buffer-filled interface. Separate power supplies control the potential at the injection end of the first capillary and at the interface; the detector is held at ground potential. Proteins are labeled with the fluorogenic reagent Chromeo P503, which preserves the isoelectric point of the labeled protein. The labeled proteins were mixed with ampholytes and injected into the first-dimension capillary. A focusing step was performed with the injection end of the capillary at high pH and the interface at low pH. To mobilize components, the interface was filled with a high pH buffer, which was compatible with the second-dimension separation. A fraction was transferred to the second-dimension capillary for separation. The process of fraction transfer and second dimension separation was repeated two dozen times. The separation produced a spot capacity of 125.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capillary array isoelectric focusing with laser-induced fluorescence detection: milli-pH unit resolution and yoctomole mass detection limits in a 32-channel system.

We report a multiplexed capillary electrophoresis system employing an array of 32 capillaries with a micromachined sheath-flow cuvette as the detection chamber. The sample streams were simultaneously excited with a 473-nm laser beam, and the fluorescence emission was imaged on a CCD camera with a pair of doublet achromat lens. The instrument produced mass detection limits of 380 +/- 120 yoctomo...

متن کامل

Whole-Column-Imaging Detection for Capillary Isoelectric Focusing and Capillary Electrophoresis

Despite the significant advantages of capillary isoelectric focusing over gel isoelectric focusing, widespread acceptance of the technique as a replacement for gel isoelectric focusing has not occurred. Several factors contribute to capillary isoelectric focusing’s slower-than-expected adoption; perhaps the most important are the performance and procedural difficulties introduced when capillary...

متن کامل

High-sensitivity laser-induced fluorescence detection for capillary electrophoresis.

Capillary electrophoresis provides very high efficiency separations of biological molecules. Laser-induced fluorescence produces very high sensitivity detection. The combination of the two techniques results in an analytical tool with unprecedented properties: separations with more than a million theoretical plates and detection limits of a few hundred analyte molecules. This paper considers th...

متن کامل

Rapid Biomolecule Analysis Using Two-dimensional Electrophoresis-electrospray Ionization Microchip

We demonstrate a two-dimensional (2D) separation microchip allowing capillary isoelectric focusing-capillary zone electrophoresis (cIEF-CZE) to be coupled to electrospray ionization mass spectrometry (ESI/MS). In the first dimension, separation is according to pI values (cIEF), while CZE occurs in the second dimension during mobilization towards the monolithically integrated ESI emitter. The se...

متن کامل

Capillary electrophoresis as a second dimension to isoelectric focusing for peptide separation.

Capillary zone electrophoresis and carrier ampholytes based capillary electrophoresis have been used as a second separation step to Off-Gel isoelectric focusing for the analysis of complex peptide mixtures. A tryptic digest of four proteins (bovine serum albumin, beta-lactoglobulin, horse myoglobin, cytochrome c) has been chosen as a peptide test mixture. After assessment of different modes of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Electrophoresis

دوره 31 15  شماره 

صفحات  -

تاریخ انتشار 2010