Health care-associated bloodstream infections associated with negative- or positive-pressure or displacement mechanical valve needleless connectors.
نویسندگان
چکیده
BACKGROUND Health care-associated, central venous catheter-related bloodstream infections (HA-BSIs) are a major cause of morbidity and mortality. Needleless connectors (NCs) are an important component of the intravenous system. NCs initially were introduced to reduce health care worker needlestick injuries, yet some of these NCs may increase HA-BSI risk. METHODS We compared HA-BSI rates on wards or intensive care units (ICUs) at 5 hospitals that had converted from split septum (SS) connectors or needles to mechanical valve needleless connectors (MV-NCs). The hospitals (16 ICUs, 1 entire hospital, and 1 oncology unit; 3 hospitals were located in the United States, and 2 were located in Australia) had conducted HA-BSI surveillance using Centers for Disease Control and Prevention definitions during use of both NCs. HA-BSI rates and prevention practices were compared during the pre-MV period, MV period, and post-MV period. RESULTS The HA-BSI rate increased in all ICUs and wards when SS-NCs were replaced by MV-NCs. In the 16 ICUs, the HA-BSI rate increased significantly when SS-NCs or needles were replaced by MV-NCs (6.15 vs 9.49 BSIs per 1000 central venous catheter [CVC]-days; relative risk, 1.54; 95% confidence interval, 1.37-1.74; P < .001). The 14 ICUs that switched back to SS-NCs had significant reductions in their BSI rates (9.49 vs 5.77 BSIs per 1000 CVC-days; relative risk, 1.65; 95% confidence interval, 1.38-1.96; p < .001). BSI infection prevention strategies were similar in the pre-MV and MV periods. CONCLUSIONS We found strong evidence that MV-NCs were associated with increased HA-BSI rates, despite similar BSI surveillance, definitions, and prevention strategies. Hospital personnel should monitor their HA-BSI rates and, if they are elevated, examine the role of newer technologies, such as MV-NCs.
منابع مشابه
Comparison of central line-associated bloodstream infection rates when changing to a zero fluid displacement intravenous needleless connector in acute care settings.
This was a multicenter, quasiexperimental, 140-month, acute care study comparing central line-associated bloodstream infection rates associated with positive or negative intravenous connectors to a zero fluid displacement connector. A decrease in central line-associated bloodstream infections was found after changing from either negative or positive intravenous connectors to the zero fluid disp...
متن کاملImpact of alcohol-impregnated port protectors and needleless neutral pressure connectors on central line-associated bloodstream infections and contamination of blood cultures in an inpatient oncology unit.
BACKGROUND A major risk factor for the development of bloodstream infection is the presence of a central venous catheter (CVC), especially in immunocompromised patients. CVC hub contamination is a risk factor for central line-associated bloodstream infection (CLABSI). METHODS This observational before-after trial in a tertiary care hospital's oncology unit included adult patients with a CVC. ...
متن کاملOutbreak of bloodstream infection temporally associated with the use of an intravascular needleless valve.
BACKGROUND Needleless intravascular catheter connector valves have been introduced into clinical practice to minimize the risk of needlestick injury. However, infection-control risks associated with these valves may be underappreciated. In March 2005, a dramatic increase in bloodstream infections was noted in multiple patient care units of a hospital in temporal association with the introductio...
متن کاملDoes the evidence support the SHEA-IDSA recommendation on the use of positive-pressure mechanical valves?
To the Editor—Few, if any, issues related to bloodstream infections and invasive devices have inspired such divergent opinions as that of needleless access connectors (ie, mechanical valves [MVs]). In a situation in which product choice is often decided on the basis of recommendations of societies such as the Society for Healthcare Epidemiology of America (SHEA) and the Infectious Diseases Soci...
متن کاملIncreased rate of catheter-related bloodstream infection associated with use of a needleless mechanical valve device at a long-term acute care hospital.
OBJECTIVE To determine whether introduction of a needleless mechanical valve device (NMVD) at a long-term acute care hospital was associated with an increased frequency of catheter-related bloodstream infection (BSI). DESIGN For patients with a central venous catheter in place, the catheter-related BSI rate during the 24-month period before introduction of the NMVD, a period in which a needle...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical infectious diseases : an official publication of the Infectious Diseases Society of America
دوره 49 12 شماره
صفحات -
تاریخ انتشار 2009