Safety and efficacy of the Aperio thrombectomy device when compared to the Solitaire AB/FR and the Revive devices in a pulsatile flow system.

نویسندگان

  • Mahdi Saleh
  • John Nathan Spence
  • Sanjeev Nayak
  • Gillian Pearce
  • Christopher Tennuci
  • Christine Roffe
چکیده

BACKGROUND AND PURPOSE There are a limited number of studies comparing the Aperio mechanical thrombectomy device to other stent-based devices. In this paper, we compared the Aperio thrombectomy device to the Solitaire AB, FR and Revive devices in a model of the middle cerebral artery (MCA) within a modified pulsatile flow system. METHODS Thrombi made of lamb's blood were placed into a pulsatile flow system perfused with Hartmann's solution at 80 bpm with a mean pressure of 90 mm Hg. 30 experiments were run with each device. RESULTS Recanalization rates were similar for all three devices (90% with the Solitaire AB, FR, 80% with the Revive, and 90% with the Aperio). The mean number of attempts to retrieve the thrombus was also similar for all three devices (1.7 with the Solitaire AB, FR, 2.1 with the Revive, 1.6 with the Aperio). Clot fragmentation and embolization rates revealed no statistical significance but there was a trend towards lower embolization rates with the Aperio (23% compared to 40% with the Solitaire AB, FR and 47% with the Revive). The Aperio was the fastest to recanalize the MCA (mean of 66 seconds compared to 186 seconds for the Solitaire AB, FR and 169 seconds for the Revive). CONCLUSIONS In this in vitro setting, the Aperio device seems to be an efficacious and safe device when compared to other similar clinically used mechanical thrombectomy devices. Larger clinical trials are warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of 2 stroke devices: the new Aperio clot-removal device and the solitaire AB/FR.

BACKGROUND AND PURPOSE Several studies have shown promising results for the use of self-expandable intracranial stents for the treatment of acute ischemic stroke. This new technique combines immediate flow restoration after stent deployment with high recanalization rates. In the present study, the safety and efficacy of the new Aperio clot-removal device was tested in comparison with the Solita...

متن کامل

Effectiveness of mechanical endovascular thrombectomy in a model system of cerebrovascular occlusion.

BACKGROUND AND PURPOSE A number of thrombectomy devices are currently undergoing clinical evaluation; meanwhile, various novel devices are under investigation. The aims of this study were to quantify flow restoration and the particle size distribution of the effluent pursuant to MET in an in vitro occlusion model. MATERIALS AND METHODS The model system was composed of 3 elements: an ICA/MCA r...

متن کامل

Histological examination of vascular damage caused by stent retriever thrombectomy devices.

BACKGROUND AND OBJECTIVES Although the recently marketed stent retriever thrombectomy devices have demonstrated a high recanalization rate and favorable clinical outcomes, there is a concern about the risks of intimal injuries when pulling out the stent in the unfolded position. In this study, the Solitaire Flow Restoration System and the Trevo retriever were used in a histopathological compari...

متن کامل

Reduction in distal emboli with proximal flow control during mechanical thrombectomy: a quantitative in vitro study.

BACKGROUND AND PURPOSE To evaluate the impact of proximal flow control on efficacy and safety of mechanical thrombectomy in an in vitro middle cerebral artery occlusion. METHODS Three independent variables, including clot type, device (Merci Retriever, Solitaire FR, and Trevo devices), and use of a balloon guide catheter, were used to ascertain the impact of proximal flow control on the size ...

متن کامل

Rapid learning curve for Solitaire FR stent retriever therapy: evidence from roll-in and randomised patients in the SWIFT trial.

BACKGROUND In light of recent positive trial data for endovascular therapy in acute ischemic stroke (AIS), stent retriever use by practitioners without prior experience with these devices may become more common. OBJECTIVE To assess the safety and efficacy of thrombectomy for AIS using Solitaire for patients treated in the roll-in period of the Solitaire With the Intention For Thrombectomy (SW...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of cardiovascular disease

دوره 2 4  شماره 

صفحات  -

تاریخ انتشار 2012