Minimally invasive reconstruction of lateral tibial plateau fractures using the jail technique: a biomechanical study
نویسندگان
چکیده
BACKGROUND This study described a novel, minimally invasive reconstruction technique of lateral tibial plateau fractures using a three-screw jail technique and compared it to a conventional two-screw osteosynthesis technique. The benefit of an additional screw implanted in the proximal tibia from the anterior at an angle of 90° below the conventional two-screw reconstruction after lateral tibial plateau fracture was evaluated. This new method was called the jail technique. METHODS The two reconstruction techniques were tested using a porcine model (n = 40). Fracture was simulated using a defined osteotomy of the lateral tibial plateau. Load-to-failure and multiple cyclic loading tests were conducted using a material testing machine. Twenty tibias were used for each reconstruction technique, ten of which were loaded in a load-to-failure protocol and ten cyclically loaded (5000 times) between 200 and 1000 N using a ramp protocol. Displacement, stiffness and yield load were determined from the resulting load displacement curve. Failure was macroscopically documented. RESULTS In the load-to-failure testing, the jail technique showed a significantly higher mean maximum load (2275.9 N) in comparison to the conventional reconstruction (1796.5 N, p < 0.001). The trend for better outcomes for the novel technique in terms of stiffness and yield load did not reach statistical significance (p > 0.05). In cyclic testing, the jail technique also showed better trends in displacement that were not statistically significant. Failure modes showed a tendency of screws cutting through the bone (cut-out) in the conventional reconstruction. No cut-out but a bending of the lag screws at the site of the additional third screw was observed in the jail technique. CONCLUSIONS The results of this study indicate that the jail and the conventional technique have seemingly similar biomechanical properties. This suggests that the jail technique may be a feasible alternative to conventional screw osteosynthesis in the minimally invasive reconstruction of lateral tibial plateau fractures. A potential advantage of the jail technique is the prevention of screw cut-outs through the cancellous bone.
منابع مشابه
Percutaneous inflation osteoplasty for indirect reduction of depressed tibial plateau fractures.
Anatomic reduction of articular depression tibial plateau fractures is challenging. The authors describe a new technique using percutaneous balloon-guided inflation osteoplasty for a depressed lateral tibial plateau fracture. The fluoroscopy-guided inflation osteoplasty restores the joint surface anatomically in a minimally invasive fashion. The metaphyseal void is filled with a fast-setting fl...
متن کاملResults of Single Lateral Locked Plate in Complex Schatzker Type V and VI Tibial Plateau Fractures Using Minimally Invasive Fixation Technique-Surgical Experience in 46 Fractures
Background:Bicondylar tibia plateau fractures are difficult to manage due to complexities of comminuation of articular surfaces, extensive soft tissue injuries, infection and risk of compartment syndrome associated with it. Various modalities including cast, traction or open reduction and internal fixation using single to dual plate fixation technique are now days used. We report our results of...
متن کاملEffectiveness of Minimally Invasive Plate Osteosynthesis (MIPO) on Comminuted Tibial or Femoral Fractures
Background: Comminuted fractures happen frequently due to traumas. Fixation without opening the fracture site,known as minimally invasive plate osteosynthesis (MIPO), has recently become prevalent. This study has beendesigned to assess the outcomes of this treatment for tibial and femoral comminuted fractures.Methods: A total of 60 patients with comminuted femoral or tibial fractures were opera...
متن کاملA case report of Schatzker type VI tibial plateau fracture treated with double reverse traction closed reduction combined with minimally invasive percutaneous plate osteosynthesis technique
RATIONALE The knee joint is an important weight-bearing joint, tibial plateau fractures affect knee function and stability. High-energy intra-articular fractures involving the tibial plateau can cause management-related problems such as wound dehiscence; severe comminution leading to malalignment; and delayed complications such as varus collapse, implant failure, and arthritis of the knee joint...
متن کاملTuberoplasty: minimally invasive osteosynthesis technique for tibial plateau fractures.
Fractures of the tibial plateau are in constant progression. They affect an elderly population suffering from a number of comorbidities, but also a young population increasingly practicing high-risk sports and using two-wheeled vehicles. The objective of this study was therefore to propose a new technique for the treatment of this type of fracture. There are a variety of classical pitfalls of c...
متن کامل