Ceramic-on-ceramic bearings in hip arthroplasty: state of the art and the future.
نویسندگان
چکیده
This systematic review of the literature summarises the clinical experience with ceramic-on-ceramic hip bearings over the past 40 years and discusses the concerns that exist in relation to the bearing combination. Loosening, fracture, liner chipping on insertion, liner canting and dissociation, edge-loading and squeaking have all been reported, and the relationship between these issues and implant design and surgical technique is investigated. New design concepts are introduced and analysed with respect to previous clinical experience.
منابع مشابه
Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature
Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...
متن کاملThe Use of Ceramics in Total Hip Arthroplasty
Ceramics have excellent mechanical properties and very stable wear characteristics and therefore have been used in many industries including automotives, aeronautics and healthcare. The use of ceramics in total hip arthroplasty has been increasing. This review article we will provide an overview of where we started and how far we have come. We will review the mechanical properties of ceramics, ...
متن کاملFracture of ceramic components as a serious failure after total hip replacement with ceramic-on-ceramic bearings
Introduction Ceramics have been introduced in total hip arthroplasty for several advantages including minimal friction, low wear, biocompatibility, no ageing problems and no problems related to the systemic increases in serum metal concentrations. In the first generation of ceramic components introduced in the 1970’s the risk of fracture was substantial, reaching up to 13.4 %. After introducing...
متن کاملFatal Cobalt Toxicity after a Non-Metal-on-Metal Total Hip Arthroplasty
This case illustrates the potential for systemic cobalt toxicity in non-metal-on-metal bearings and its potentially devastating consequences. We present a 71-year-old male with grinding sensations in his right hip following ceramic-on-ceramic total hip arthroplasty (THA). After diagnosing a fractured ceramic liner, the hip prosthesis was revised into a metal-on-polyethylene bearing. At one year...
متن کاملWhat every surgeon should know about Ceramic-on-Ceramic bearings in young patients
Based on the exceptional tribological behaviour and on the relatively low biological activity of ceramic particles, Ceramic-on-Ceramic (CoC) total hip arthroplasty (THA) presents significant advantagesCoC bearings decrease wear and osteolysis, the cumulative long-term risk of dislocation, muscle atrophy, and head-neck taper corrosion.However, there are still concerns regarding the best techniqu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 94 6 شماره
صفحات -
تاریخ انتشار 2012