The Extent of the Crack on Artificial Simulation Models with CBCT and Periapical Radiography
نویسندگان
چکیده
BACKGROUND The aim of this study was to investigate the extent of the crack of a cracked tooth on an artificial simulation model with Periapical Radiography (PR) and cone beam computed tomography (CBCT) in vitro, providing the basis for early diagnosis and an appropriate treatment plan. METHODS Forty-four teeth with different extents of artificial cracks, created by exposure to liquid nitrogen after hot water at 100°C, were collected. They were subjected to PR and CBCT. Micro-computed tomography (micro-CT) examination, regarded as a relatively more accurate measurement than others, was used to measure and record the crack depth. Three observers, an endodontic graduate student, an experienced endodontist, and an experienced radiologist, examined the PR and CBCT results independently, and the presence or absence of cracks with PR and CBCT were respectively recorded. The external consistency ICC with 95% confidence interval (95% CI) was used to analyze the consistency among the graduate student, endodontist, and radiologist; ROC curves were used for the analysis of diagnostic performance of both radiographic modalities for tooth cracks with crack depth. RESULTS For the interpretation of the PR results, there were statistically significant differences among the three different observers (P < 0.001), and the interpretation of the CBCT results (P < 0.001). In the group of results read by the graduate student, the sensitivity of diagnosis with CBCT and PR was 77.27% and 22.73%, respectively (P < 0.001). In the group of results read by the endodontist, the sensitivity of diagnosis with CBCT and PR was 81.81% and 8.19%, respectively (P < 0.001). In the group of results read by the radiologist, the sensitivity of diagnosis with CBCT and PR was 88.64% and 11.36%, respectively (P < 0.001). As for CBCT diagnosis, the critical value for the graduate, endodontist, and radiologist was 3.20 mm, 2.06 mm, and 1.24 mm, respectively. For the PR diagnosis, the critical value for the graduate, endodontist, and radiologist was 6.12 mm, 6.94 mm, and 6.94 mm, respectively. CONCLUSIONS Within the limitations of this study, on an artificial simulation model of cracked teeth for early diagnosis, we recommend that it would be better for a cracked tooth to be diagnosed by a radiologist with CBCT than PR, CBCT with a minimum depth of 1.24 mm.
منابع مشابه
مقایسه دوز پرتویی و کیفیت تصویر توموگرافی کامپیوتری مولتی اسلایس (MSCT) معمولی، توموگرافی کامپیوتری پرتو مخروطی (CBCT) و رادیوگرافی پری اپیکال در تصویربرداری دندانپزشکی
Background and Aims: With the increasing use of CT (Computed Tomoghraphy) scans in dentistry especially in the implantology, there may be significant increases in the radiation exposure and its risk. During the last year’s ConeBeam Computed Tomoghraphy (CBCT) has been introduced as an imaging modality for dentistry. The aim of this review article was to present comprehensive inform...
متن کاملDetection of periapical bone defects in human jaws using cone beam computed tomography and intraoral radiography.
AIM To compare the diagnostic accuracy of intraoral digital periapical radiography with that of cone beam computed tomography (CBCT) for the detection of artificial periapical bone defects in dry human jaws. METHODOLOGY Small and large artificial periapical lesions were prepared in the periapical region of the distal root of six molar teeth in human mandibles. Scans and radiographs were taken...
متن کاملComparison of Cone Beam Computerized Tomography and Phosphor Storage Plate in Detecting Artificial Buccal Recurrent Caries
Introduction Recurrent or secondary caries develops at the margin of restorations and causes restorative failure. We conducted this study to compare the performance of Phosphor Storage Plate (PSP) and Cone Beam Computed Tomography (CBCT) scan in detecting buccal recurrent caries under amalgam and composite resin restorations. Materials and Methods Class V cavities were prepared on the buccal...
متن کاملDiagnostic accuracy of small volume cone beam computed tomography and intraoral periapical radiography for the detection of simulated external inflammatory root resorption.
AIM To compare in an ex vivo model the ability of digital intraoral radiography and cone beam computed tomography (CBCT) to detect simulated external inflammatory root resorption lesions, and to investigate the effect of altering the degree of rotation of the CBCT scanners X-ray source and imaging detector on the ability to detect the same lesions. METHODOLOGY Small and large simulated extern...
متن کاملComparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects
Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects. Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...
متن کامل