Recording pressure at the distal end of the endotracheal tube to measure respiratory impedance.

نویسندگان

  • D Navajas
  • R Farré
  • M Rotger
  • J Canet
چکیده

To minimize the flow-dependent effects caused by an endotracheal tube during impedance measurements, we recorded pressure inside the tube at its distal end. We used a commercial endotracheal tube with a lumen built into its wall with the opening located near the outlet of the tube. We characterized the effect of the tube by means of an effective transfer function (H). We measured H from 0.25-32 Hz on a mechanical analogue by using pseudorandom excitation with different peak-to-peak flow amplitudes (Vpp). For an 8 mm internal diameter (ID) endotracheal tube the modulus of H measured with Vpp 0.2 l.s-1 was 1.00 at 0.25 Hz and increased with the frequency to 1.40 at 32 Hz. The phase factor was close to zero (less than 5 degrees) over the whole frequency band. The modulus of H changed less than 5% and the phase factor less than 3 degrees when Vpp was increased from 0.2 to 0.8 l.s-1. We evaluated the method on five mechanical analogues with increased resistance or elastance and with a different tracheal area. The mean normalized distance in the complex plane over the whole frequency band (dz) between the analogue impedance and the estimated value from intubation was always less than 5%. Finally, the method was tested on an active analogue which superimposed a high-amplitude (up to 1.4 l.s-1 peak-to-peak) low-frequency (0.25 or 0.33 Hz) sinusoidal flow onto excitation: dz was always less than 4.3%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی اندازه‌گیری و کنترل فشار کاف لوله داخل تراشه بیماران بستری در بخش مراقبت‌های ویژه

  Background and Objective: The objective of this study was to investigate the endotracheal tube cuff (ETT) pressure in the intensive care unit (ICU) patients, who had been intubated.     Meterials and Methods: All patients were placed in ICU during the last three month 2008. The endotracheal tube cuff (ETT) pressure in 308 cases was measured at twice by an expert. A standard manometer was used...

متن کامل

بررسی تاثیر تغییر وضعیت بدن بر فشار کاف لوله تراشه در بیماران تحت تهویه مکانیکی

Background: Endotracheal tube cuff pressure must be maintained in safe range. Many factors could be affecting on endotracheal tube cuff pressure in patients on mechanical ventilation. Patients undergoing mechanical ventilation (MV) in critical care settings require changing position for different reasons. The aim of this study was to determine the effect of changes in body position and head of ...

متن کامل

A new correction technique for measuring respiratory impedance through an endotracheal tube.

Measurement of respiratory impedance (Zrs) in intubated patients requires corrections for flow-dependent resistance and air compression inside the endotracheal tube (ET). The purpose of this study was to test a new correction technique for these effects. We therefore studied 110 patients in two conditions: breathing normally (C1), or breathing through an ET placed at the mouth (C2). In C1, we m...

متن کامل

Study of endotracheal tube cuff pressure and time of measurement among intensive care units patients

Introduction: The pressure in the endotracheal tube cuff must be kept within an optimal range, to make sure tracheal capillaries circulation still stable during positive ventilation. This is essential to avoid oral and gastric stuffing aspiration Objective: The objective of this study was to assess the endotracheal tube cuff pressure and time intervals measurements among intensive care units...

متن کامل

The effect of dexmedetomidine on the hemodynamic responses of endotracheal extubation and sedation level in recovery after cholecystectomy

Background: Emergence from general anesthesia and removing of tracheal tube can be associated with coughing, agitation, and hemodynamic disturbances. Dexmedetomidine is an alpha two adrenoceptor agonist that has effective sedation with less cardiovascular unstability and respiratory depression and may be useful for extubation and prevention of hemodynamic response during tracheal tube removing....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 2 2  شماره 

صفحات  -

تاریخ انتشار 1989