Evaluation of fluence‐smoothing feature for three IMRT planning systems
نویسندگان
چکیده
Commercially available intensity-modulated radiation therapy (IMRT) inverse treatment planning systems (ITPS) typically include a smoothing function which allows the user to vary the complexity of delivered beam fluence patterns. This study evaluated the behavior of three ITPSs when varying smoothing parameters. We evaluated four cases treated with IMRT in our clinic: sinonasal carcinoma (SNC), glioblastoma multiforme (GBM), base of tongue carcinoma (BOT), and prostate carcinoma (PST). Varian Eclipse v6.5, BrainLAB BrainScan v5.31, and Nomos Corvus v6.2 ITPSs were studied for the SNC, GBM, and PST sites. Only Eclipse and Corvus were studied for BOT due to field size constraints of the BrainLAB MM3 collimator. For each ITPS, plans were first optimized using vendor- recommended default "smoothing" values. Treatment plans were then reoptimized, exploring various smoothing values. Key metrics recorded included a delivery complexity (DC) metric and the Ian Paddick Conformality Index (IPCI). Results varied widely by vendor with regard to the impact of smoothing on complexity and conformality. Plans run on the Corvus ITPS showed the logically anticipated increase in DC as smoothing was decreased, along with associated improved organ-at-risk (OAR) sparing. Both Eclipse and BrainScan experienced an expected trend for increased DC as smoothing was decreased. However, this increase did not typically result in appreciably improved OAR sparing. For Eclipse and Corvus, and to a much lesser extent BrainScan, increases in smoothing decreased DC but eventually caused unacceptable losses in plan quality. Depending on the ITPS, potential benefits from optimizing fluence smoothing levels can be significant, allowing for increases in either efficiency or conformality. Because of variability in smoothing function behavior by ITPS, it is important that users familiarize themselves with the effects of varying smoothing parameters for their respective ITPS. Based on experience gained here, we provide recommended workflows for each ITPS to best exploit the fluence-smoothing features of the system.
منابع مشابه
Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کاملWhat is an acceptably smoothed fluence? Dosimetric and delivery considerations for dynamic sliding window IMRT
BACKGROUND The study summarised in this report aimed to investigate the interplay between fluence complexity, dose calculation algorithms, dose calculation spatial resolution and delivery characteristics (monitor units, effective field width and dose delivery against dose prediction agreement) was investigated. A sample set of complex planning cases was selected and tested using a commercial tr...
متن کاملFLUENCE MAP OPTIMIZATION IN INTENSITY MODULATED RADIATION THERAPY FOR FUZZY TARGET DOSE
Although many methods exist for intensity modulated radiotherapy (IMRT) fluence map optimization for crisp data, based on clinical practice, some of the involved parameters are fuzzy. In this paper, the best fluence maps for an IMRT procedure were identifed as a solution of an optimization problem with a quadratic objective function, where the prescribed target dose vector was fuzzy. First, a d...
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملA quantitative study of IMRT delivery effects in commercial planning systems for the case of oesophagus and prostate tumours.
This study focuses on understanding the impact of intensity-modulated radiotherapy (IMRT) delivery effects when applied to plans generated by commercial treatment-planning systems such as Pinnacle (ADAC Laboratories Inc.) and CadPlan/Helios (Varian Medical Systems). These commercial planning systems have had several version upgrades (with improvements in the optimization algorithm), but the IMR...