Influence of the preimplantation QRS axis on responses to cardiac resynchronization therapy.

نویسندگان

  • Javier García-Seara
  • José L Martínez-Sande
  • Belén Cid
  • Francisco Gude
  • María Bastos
  • Miguel Domínguez
  • Alfonso Varela
  • José R González-Juanatey
چکیده

INTRODUCTION AND OBJECTIVES The aim of this study was to determine whether measurement of the QRS axis can help to predict outcome in patients undergoing cardiac resynchronization therapy. METHODS The study included 78 patients who had undergone successful cardiac resynchronization device implantation. Patients were classified as having either a normal QRS axis (i.e., between -30 degrees and +120 degrees) or a left QRS axis deviation (i.e., between -30 degrees and -90 degrees). Patients were regarded as responders if they fulfilled all of the following criteria: their functional class improved by at least one grade, their left ventricular ejection fraction increased by at least 5%, they did not need hospitalization for worsening heart failure, and they were still alive at 12-month follow-up. RESULTS After adjustment for age, preimplantation left ventricular ejection fraction, etiology and mitral regurgitation, a statistically significant interaction was found between the QRS axis and lead location (P=.026). There was a better response with an anterior lead location if the patient had a left QRS axis deviation. CONCLUSIONS A significant interaction was found between the lead location and the preimplantation QRS electrical axis, such that there was a better response to resynchronization therapy when the lead was implanted in the anterior interventricular vein if the patient had a left QRS axis deviation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Paced left ventricular QRS width and ECG parameters predict outcomes after cardiac resynchronization therapy: PROSPECT-ECG substudy.

BACKGROUND For patients with symptomatic New York Heart Association class III or IV, ejection fraction ≤ 35%, and QRS ≥ 130 ms, cardiac resynchronization therapy (CRT) has become an established treatment option. However, use of these implant criteria fails to result in clinical or echocardiographic improvement in 30% to 45% of CRT patients. METHODS AND RESULTS The Predictors of Response to CR...

متن کامل

Influence of Intrinsic Myocardial Conduction on Paced QRS Morphology During Cardiac Resynchronization Therapy Follow up

We report two cases of patients of cardiac resynchronization therapy (CRT) whose ECGs, during follow up, showed different paced QRS morphology as compared to those of immediate post-device implantation. Parameters of leads, including sensitivity and capture thresholds, were unchanged. There was no lead dislodgement confirmed on fluoroscopy. The ECGs obtained in device off mode showed different ...

متن کامل

Left ventricular apical wall motion abnormality is associated with lack of response to cardiac resynchronization therapy in patients with ischemic cardiomyopathy.

BACKGROUND Many patients with appropriate indications fail to respond to cardiac resynchronization therapy (CRT). OBJECTIVE The purpose of our study was to determine the relationship between CRT response and preimplantation apical wall motion abnormality. METHODS We analyzed data from 83 patients with ischemic cardiomyopathy who underwent CRT. All patients had New York Heart Association cla...

متن کامل

Cardiac resynchronization therapy in patients with a narrow QRS complex.

OBJECTIVES The purpose of this study was to evaluate the effects of cardiac resynchronization therapy (CRT) in heart failure patients with narrow QRS complex (<120 ms) and evidence of left ventricular (LV) dyssynchrony on tissue Doppler imaging (TDI). BACKGROUND Cardiac resynchronization therapy is beneficial in selected heart failure patients with wide QRS complex (> or =120 ms). Patients wi...

متن کامل

Electrocardiographic predictors of response to cardiac resynchronization therapy in patients with intraventricular conduction delay.

BACKGROUND Little is known about predictors of response to cardiac resynchronization therapy (CRT) in patients with intraventricular conduction delay (IVCD). The purpose of this study was to investigate the benefits of CRT and significant variables on surface electrocardiogram (ECG) to predict response to CRT in those patients. METHODS AND RESULTS Among the cohort of 152 CRT patients, 40 pati...