Reducing the airflow waveform distortions from breathing style and body position with improved calibration of respiratory effort belts

نویسندگان

  • Tiina M Seppänen
  • Olli-Pekka Alho
  • Tapio Seppänen
چکیده

BACKGROUND Respiratory effort belt measurement is a widely used method to monitor respiration. Signal waveforms of respiratory volume and flow may indicate pathological signs of several diseases and, thus, it would be highly desirable to predict them accurately. Calibrated effort belts are sufficiently accurate for estimating respiratory rate, but the respiratory volume and flow prediction accuracies degrade considerably with changes in the subject's body position and breathing style. METHODS An improved calibration method of respiratory effort belts is presented in this paper. It is based on an optimally trained FIR (Finite Impulse Response) filter bank constructed as a MISO system (Multiple-Input Single-Output) between respiratory effort belt signals and the spirometer in order to reduce waveform errors. Ten healthy adult volunteers were recruited. Breathing was varied between the following styles: metronome-guided controlled breathing rate of 0.1 Hz, 0.15 Hz, 0.25 Hz and 0.33 Hz, and a free rate that was felt normal by each subject. Body position was varied between supine, sitting and standing. The proposed calibration method was tested against these variations and compared with the state-of-the-art methods from the literature. RESULTS Relative waveform error decreased 60-70% when predicting airflow under changing breathing styles. The coefficient of determination R2 varied between 0.88-0.95 and 0.65-0.79 with the proposed and the standard method, respectively. Standard deviation of respiratory volume error decreased even 80%. The proposed method outperformed other methods. CONCLUSIONS Results show that not only the respiratory volume can be computed more precisely from the predicted airflow, but also the flow waveforms are very accurate with the proposed method. The method is robust to breathing style changes and body position changes improving greatly the accuracy of the calibration of respiratory effort belts over the standard method. The enhanced accuracy of the belt calibration offers interesting opportunities, e.g. in pulmonary and critical care medicine when objective measurements are required.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The efficacy of diaphragmatic breathing practice on respiratory function, balance, and quality of life in elderly women

Introduction: Introduction: The respiratory system affects the motor control and stability of the body, especially in the elderly. The present study aimed to determine the effect of diaphragmatic breathing practice on respiratory function, balance, and quality of life in elderly women. Materials and Methods: Forty elderly women with a mean age of 72.40 years participated in this study voluntari...

متن کامل

The Diagnosis of Sleep Apnea Typically In- Volves an Overnight Polysomnogram with Continuous Monitoring of Several Physi-

1521 THE DIAGNOSIS OF SLEEP APNEA TYPICALLY INVOLVES AN OVERNIGHT POLYSOMNOGRAM WITH CONTINUOUS MONITORING OF SEVERAL PHYSIOLOGIC parameters and surrogate measures of airflow (nasal pressure [Pn], oronasal thermistor, expired CO2 waveform [PECO2]) using contact sensors. 1-5 A subject can come in contact with at least 20 such sensors during a study. These sensors and the wires can influence not ...

متن کامل

Consequences of postural changes and removal of vestibular inputs on the movement of air in and out of the lungs of conscious felines.

A variety of experimental approaches in human subjects and animal models established that the vestibular system contributes to regulation of respiration. In cats, the surgical elimination of labyrinthine signals produced changes in the spontaneous activity and posturally related responses of a number of respiratory muscles. However, these effects were complex and sometimes varied between muscle...

متن کامل

Novel whole body plethysmography system for the continuous characterization of sleep and breathing in a mouse.

Sleep is associated with marked alterations in ventilatory control that lead to perturbations in respiratory timing, breathing pattern, ventilation, pharyngeal collapsibility, and sleep-related breathing disorders (SRBD). Mouse models offer powerful insight into the pathogenesis of SRBD; however, methods for obtaining the full complement of continuous, high-fidelity respiratory, electroencephal...

متن کامل

A Numerical Simulation of Inspiratory Airflow in Human Airways during Exercise at Sea Level and at High Altitude

At high altitudes, the air pressure is much lower than it is at sea level and contains fewer oxygen molecules and less oxygen is taken in at each breath. This requires deeper and rapid breathing to get the same amount of oxygen into the blood stream compared to breathing in air at sea level. Exercises increase the oxygen demand and make breathing more difficult at high altitude. In this study, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2013