Experimental Investigation of Small Diameter Two - Phase Closed Thermosy - phons Charged with Water , FC - 84 , FC - 77 & FC - 3283

نویسندگان

  • Hussam Jouhara
  • Anthony J. Robinson
چکیده

An experimental investigation of the performance of thermosyphons charged with water as well as the dielectric heat transfer liquids FC-84, FC-77 and FC-3283 has been carried out. The copper thermosyphon was 200 mm long with an inner diameter of 6 mm, which can be considered quite small compared with the vast majority of thermosyphons reported in the open literature. The evaporator length was 40 mm and the condenser length was 60 mm which corresponds with what might be expected in compact heat exchangers. With water as the working fluid two fluid loadings were investigated, that being 0.6 ml and 1.8 ml, corresponding to approximately half filled and overfilled evaporator section in order to ensure combined pool boiling and thin film evaporation/boiling and pool boiling only conditions respectively. For the Flourinert liquids, only the higher fill volume was tested as the aim was to investigate pool boiling opposed to thin film evaporation. Generally, the water charged thermosyphon evaporator and condenser heat transfer characteristics compared well with available predictive correlations and theories. The thermal performance of the water charged thermosyphon also outperformed the other three working fluids in both the effective thermal resistance as well as maximum heat transport capabilities. Even so, FC-84, the lowest saturation temperature fluid tested, shows marginal improvement in the heat transfer at low operating temperatures. All of the tested Flourinert liquids offer the advantage of being dielectric fluids, which may be better suited for sensitive electronics cooling applications and were all found to provide adequate thermal performance up to approximately 30-50 W after which liquid entrainment compromised their performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Plant growth promoting rhizobacteria (PGPR) improve plant growth, antioxidant capacity, and essential oil properties of lemongrass (Cymbopogon citratus) under water stress

Among abiotic stresses, drought is considered as the most important growth limiting factor, especially in arid and semiarid regions. Drought impacts can be adjusted by soil microorganisms. Accordingly, the present study was organized in order to the increase the tolerance of lemongrass (Cymbopogon citratus)to drought using plant growth promoting rhizobacteria (PGPR). Treatments were wa...

متن کامل

Effects of Soil Moisture Deficit Levels at Irrigation time on Shoot and Root Growth Indices, Yield and Water Use Efficiency of Greenhouse Cucumber

The aim of this study was to evaluate the effect of different levels of soil moisture at irrigation time on root growth, yield and water use efficiency of greenhouse cucumber (Cucumis sativus L.), Yalda cultivar. The experiment was conducted in a randomized complete block design with six treatments and three replications in Isfahan Greenhouse Research Center in 2016. These experimental treatmen...

متن کامل

پاسخ‌های مورفو فیزیولوژیک ذرت به تنش خشکی در مراحل مختلف رشد در منطقه نیمه خشک شمال فارس

In order to evaluate morpho-physiological responses of hybrid corn KSC750 to water stress at various stages of growth, a field experiment was conducted at the Pasargad region (northwest Fars) in 2010. The experiment carried out as a randomized complete block design, with 3 replications. In this study, corn growth period was divided into three phases: the establishment of plant to tasseling (pha...

متن کامل

Effects of Vermicompost on Growth Parameters, Water Use Efficiency and Quality of Zinnia Bedding Plants (Zinnia elegance ‘Dreamland Red’) under Different Irrigation Regimes

The drastic decline of precipitation over the past decade along with overuse of chemical inputs and consequent soil fertility reduction are the most important problems in the approach to agricultural expansion, particularly in urban landscaping. Therefore, an experiment was designed to examine the effects of different irrigation levels (40, 70 and 100 % of field capacity, or FC) and different v...

متن کامل

An advanced expiratory circuit for the recovery of perfluorocarbon liquid from non-saturated perfluorocarbon vapour during partial liquid ventilation: an experimental model

BACKGROUND The loss of perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be minimized both to prevent perfluorocarbon vapour entering the atmosphere and to re-use the recovered PFC liquid. Using a substantially modified design of our previously described condenser, we aimed to determine how much perfluorocarbon liquid could be recovered from gases contai...