Development of a Microsensor to Minimize Post Cataract Surgery Complications

نویسندگان

  • M. Mottaghi
  • F. Ghalichi
  • H. Badri Ghavifekr
  • H. Niroomand Oskui
چکیده

This paper presents design and characterization of a microaccelerometer designated for integration into cataract surgical probe to detect hardness of different eye tissues during cataract surgery. Soft posterior lens capsule of eye can be easily damaged in comparison with hard opaque lens since the surgeon can not see directly behind cutting needle during the surgery. Presence of microsensor helps the surgeon to avoid rupturing posterior lens capsule which if occurs leads to severe complications such as glaucoma, infection, or even blindness. The microsensor having overall dimensions of 480 μm x 395 μm is able to deliver significant capacitance variations during encountered vibration situations which makes it capable to distinguish between different types of tissue. Integration of electronic components on chip ensures high level of reliability and noise immunity while minimizes space and power requirements. Physical characteristics and results on performance testing, proves integration of microsensor as an effective tool to aid the surgeon during this procedure. Keywords—Cataract surgery, MEMS, Microsensor, Phacoemulsification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی و مقایسه تأثیر آتراکوریوم و پانکرونیوم بر روی فشار داخل کره چشم در اعمال جراحی کاتاراکت

Introduction: Cataract is an opacified lens and senile cataract is a common disorder. It is desirable to reduce intraocular pressure (IOP) in order to minimize intra and post operative difficulties and complications. Many researches have studied the effects of muscle relaxants on IOP. Comparison effect of atracurium and pancuronium on IOP has been evaluated in one study with a small sample size...

متن کامل

Comparative evaluation of post operative uveitis following use of viscoelastic (Methyl cellulose gel or healon) and air in patients C cataract surgery and lens implantation

Background: Cataract surgery lens implantation is the most common eye surgery that good quality of operation can help good visual outcome. One of the most common complication following cataract surgery is uveitis that usualy occur in first few weeks after operation. The aim of the present study was to compare the incidence of the post operative uveitis between viscoelastic substance and air in...

متن کامل

Visual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus

Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...

متن کامل

کاربرد لنزهای داخل چشمی در جراحی کاتاراکت و عوامل تأثیرگذار بر دید بیمار

Introduction: With the growing and rapid development of refractive surgery, researches focus increasingly on improvement of visual quality after cataract surgery. Intraocular lenses (IOLs) were a successful effort in the field of cataract surgery. Despite significant advances in cataract surgery, several complications related to surgical technique and IOL design after surgery can cause vision c...

متن کامل

The comparison of efficacy and complications of two premedication agents, midazolam-ketamine and midazolam-fentanyl in adult patients who underwent cataract surgery

Background: Cataract is one of the most common eye diseases especially in children and adolescents in two age ranges, and many of these patients need to surgery throughout life. The purpose of this study was to compare the efficacy and side effects of midazolam-ketamine and midazolam-fentanyl for sedation in adult cataract surgery. Methods: In this study, which was a case-control study, 80 pat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012