Update on stents: Recent studies on the TAXUS® stent system in small vessels

نویسندگان

  • Shuzou Tanimoto
  • Joost Daemen
  • Patrick W Serruys
چکیده

Small vessel size (<3 mm) has been identified as an independent predictive factor of restenosis after percutaneous coronary intervention when using bare metal stents (BMS). It remains controversial whether BMS placement in small vessels has an advantage over balloon angioplasty in terms of angiographic and clinical outcomes. The advent of drug eluting stents (DES), either paclitaxel-eluting stents (PES) or sirolimus-eluting stents (SES), has strongly impacted interventional cardiology by significantly reducing restenosis and the need for repeat revascularization. Therefore, it was also expected that DES could substantially reduce restenosis in smaller vessels. However, even in the DES era, small vessel size remains an independent predictor of angiographic and clinical restenosis. To date, only a few studies systematically investigate the clinical effect of DES placement in small vessels. In addition, some potential issues with the use of DES have been raised, such as late stent thrombosis and late restenosis. In order to (i) establish the superiority of DES over BMS; (ii) verify the efficacy and safety of DES; and (iii) critically assess the superiority of one DES over the other in patients with small coronary arteries, further multicenter, randomized clinical trials with larger sample size are warranted.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduced risk of restenosis in small vessels and reduced risk of myocardial infarction in long lesions with the new thin-strut TAXUS Liberté stent: 1-year results from the TAXUS ATLAS program.

OBJECTIVES The TAXUS ATLAS Small Vessel (SV) and Long Lesion (LL) multicenter studies compared the performance of the thin-strut (0.0038 inch) TAXUS Liberté 2.25-mm stent (Boston Scientific; Natick, Massachusetts) and the TAXUS Liberté 38-mm long stent (Boston Scientific; Natick, Massachusetts) with the earlier paclitaxel-eluting TAXUS Express (Boston Scientific) stent that has identical polyme...

متن کامل

Impact of drug-eluting stents on distal vessels.

BACKGROUND Previous studies have not addressed vessel response >5 mm distal to the stent edge. Therefore, we investigated the impact of paclitaxel-eluting stents (PES) versus bare metal stents (BMS) on distal vessels in the serial intravascular ultrasound substudies of TAXUS IV, V, and VI. METHODS AND RESULTS TAXUS IV, V, and VI were double-blind, randomized, multicenter, controlled trials co...

متن کامل

Sirolimus and Paclitaxel on polymer-based drug-eluting stents: similar but different.

Recent clinical studies that investigated the efficacy of the two U.S. Food and Drug Administration-approved drug-eluting stent (DES) platforms Cypher (Cordis, Johnson and Johnson, Miami Lakes, Florida) and Taxus (Boston Scientific, Boston, Massachusetts) suggest that there are differences between both DES concerning neointimal growth. Both DES elute compounds that inhibit the cell cycle, but a...

متن کامل

A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: Design and statistical methods of the PERSEUS clinical program

BACKGROUND Paclitaxel-eluting stents decrease angiographic and clinical restenosis following percutaneous coronary intervention compared to bare metal stents. TAXUS Element is a third-generation paclitaxel-eluting stent which incorporates a novel, thinner-strut, platinum-enriched metal alloy platform. The stent is intended to have enhanced radiopacity and improved deliverability compared to oth...

متن کامل

DRUG ELUTING STENTS Cypher Versus Taxus: Are There Differences?

Today, drug-eluting stents (DES) are the standard stenting procedure in the USA and in Switzerland. The objective of this analysis is to answer the two questions: what clinically relevant data regarding DES have been published, and is there a clinically relevant difference between the Cypher and the Taxus stents? Twenty-two randomized, controlled studies with a total of 11,118 patients were ide...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Vascular Health and Risk Management

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2007