CARDIOVASCULAR MEDICINE Acute improvement of atrial mechanical stunning after electrical cardioversion of persistent atrial fibrillation: comparison between biatrial and single atrial pacing

نویسندگان

  • M Takagi
  • A Doi
  • N Shirai
  • K Hirata
  • Y Takemoto
  • K Takeuchi
  • J Yoshikawa
چکیده

Objective: To evaluate the acute effects of atrial pacing at different pacing sites on mechanical stunning after cardioversion of atrial fibrillation (AF). Setting: Tertiary referral centre. Patients: 20 patients with persistent AF were studied. Interventions: Spontaneous echo contrast (SEC), left atrial appendage emptying velocity (LAAEV), and left atrial appendage emptying fraction (LAAEF) were assessed by transoesophageal echocardiography (TOE) during AF, after conversion to sinus rhythm, and during atrial pacing from the right atrial appendage, left lateral atrium, and both atria simultaneously. Transmitral inflow velocity of the atrial wave (TMIF-A) by TOE and the maximum P wave duration in 12 lead ECG were also measured during sinus rhythm and atrial pacing. Main outcome measures: Comparison of atrial mechanical function and P wave duration in 12 lead ECG during atrial pacing from different sites after cardioversion of AF. Results: Compared with sinus rhythm, atrial pacing at 80 beats/min increased LAAEV from mean (SD) 14.6 (10.1) to 33.4 (19.8) cm/s (p = 0.001), LAAEF from 13.8 (8.5) to 32.1 (11.2)% (p , 0.001), and TMIF-A from 24.6 (11.9) to 45.6 (21.0) cm/s (p , 0.001) and reduced SEC grade from 2.6 (1.0) to 1.6 (0.9) (p , 0.001). These effects had a positive force–frequency relation. Biatrial pacing produced the shortest P wave duration and resulted in the most significant improvement in atrial function (LAAEV, 33.2 (19.3) v 53.7 (23.9) cm/s, p = 0.0001; LAAEF, 31.9 (11.1) v 46.2 (12.6)%, p , 0.0001; TMIF-A, 37.7 (18.3) v 54.1 (21.2) cm/s, p , 0.001; SEC grade, 1.4 (1.1) v 0.8 (0.9), p = 0.001, right atrial appendage versus biatrial pacing). Conclusions: Atrial pacing at increased rates can improve atrial mechanical function after cardioversion of persistent AF. Biatrial pacing may be the most effective technique to reverse atrial mechanical stunning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute improvement of atrial mechanical stunning after electrical cardioversion of persistent atrial fibrillation: comparison between biatrial and single atrial pacing.

OBJECTIVE To evaluate the acute effects of atrial pacing at different pacing sites on mechanical stunning after cardioversion of atrial fibrillation (AF). SETTING Tertiary referral centre. PATIENTS 20 patients with persistent AF were studied. INTERVENTIONS Spontaneous echo contrast (SEC), left atrial appendage emptying velocity (LAAEV), and left atrial appendage emptying fraction (LAAEF) ...

متن کامل

Electrical remodeling of the atria following loss of atrioventricular synchrony: a long-term study in humans.

BACKGROUND Evidence suggests that an increased incidence of atrial fibrillation occurs in patients undergoing single-chamber ventricular pacing (VVI) when compared with those undergoing single-chamber atrial pacing (AAI) or those having dual-chamber atrioventricular pacing (DDD). The mechanism for this is unknown. We hypothesized that long-term loss of atrioventricular (AV) synchrony leads to a...

متن کامل

Left Atrial 4D Blood Flow Dynamics and Hemostasis following Electrical Cardioversion of Atrial Fibrillation

Background: Electrical cardioversion in patients with atrial fibrillation is followed by a transiently impaired atrial mechanical function, termed atrial stunning. During atrial stunning, a retained risk of left atrial thrombus formation exists, which may be attributed to abnormal left atrial blood flow patterns. 4D Flow cardiovascular magnetic resonance (CMR) enables blood flow assessment from...

متن کامل

Acute haemodynamic benefits of biatrial atrioventricular sequential pacing: comparison with single atrial atrioventricular sequential pacing.

OBJECTIVE To evaluate the acute effects on haemodynamic variables of biatrial pacing in comparison with high right atrial (HRA) pacing and left lateral atrial pacing. PATIENTS AND DESIGN 23 patients were paced from the HRA site, the lateral site of the coronary sinus (CS), and both sites on two fixed atrioventricular delays (100 and 150 ms) during atrioventricular sequential pacing at 80 and ...

متن کامل

Reversal of atrial mechanical dysfunction after cardioversion of atrial fibrillation: implications for the mechanisms of tachycardia-mediated atrial cardiomyopathy.

BACKGROUND Atrial mechanical "stunning" develops after cardioversion of atrial fibrillation (AF) and is implicated in the genesis of thromboembolic complications. However, the mechanisms responsible for this phenomenon are poorly understood. Whether atrial mechanical dysfunction caused by AF can be reversed by pacing at increased rates or by pharmacological agents is unknown. METHODS AND RESU...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004