Intra-operative error during Austin Moore hemiarthroplasty.

نویسنده

  • P Weinrauch
چکیده

PURPOSE To examine the frequency of technical errors during implantation of the Austin Moore prosthesis in a public hospital. METHODS Radiographs and charts of 147 consecutive uncemented Austin Moore hemiarthoplasty patients were retrospectively reviewed with particular reference to intra-operative errors associated with early failure of the prosthesis. RESULTS 48% of the patients had at least one error pertinent to implantation and 14% sustained intra-operative fractures. The error rates between relatively junior doctors and consultants were not significantly different. CONCLUSION The uncemented Austin Moore prosthesis is a technically demanding prosthesis that is difficult to implant well. Greater selectivity should be exercised when considering its use for femoral neck fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of laminar air-flow on the results of Austin-Moore hemiarthroplasty.

INTRODUCTION A second cycle audit to evaluate the results after introduction of water impervious surgical gowns and drapes while performing Austin-Moore hemiarthroplasty as recommended by our previously published study. AIM To assess the difference in the re-operation rate following Austin-Moore hemiarthroplasty between procedures performed under laminar air-flow to those performed in convent...

متن کامل

Cemented versus uncemented hemiarthroplasty for intracapsular hip fractures: A randomised controlled trial in 400 patients.

We undertook a prospective randomised controlled trial involving 400 patients with a displaced intracapsular fracture of the hip to determine whether there was any difference in outcome between treatment with a cemented Thompson hemiarthroplasty and an uncemented Austin-Moore prosthesis. The surviving patients were followed up for between two and five years by a nurse blinded to the type of pro...

متن کامل

Intraoperative Periprosthetic Femoral Fractures Related to Austin Moore Hemiarthroplasty—A Retrospective Review of 365 Patients

Intraoperative periprosthetic femoral fractures (IPFF) have been studied extensively for total hip arthroplasties, but not for hemiarthroplasties. Recent series in the literature show an IPFF rate for hemiarthroplasties ranging from 0% to 14%. The present study was designed to determine the prevalence and outcome after IPFF during non-cemented hemiarthroplasty. In addition, the surgical step at...

متن کامل

Is It Time to Phase Out the Austin Moore Hemiarthroplasty? A Propensity Score Matched Case Control Comparison versus Cemented Hemiarthroplasty

We compared the Austin Moore hemiarthroplasty versus cemented hemiarthroplasties using a propensity score matched cased control study. For a consecutive cohort of 450 patients with displaced intracapsular neck of femur fractures, 128 matched cases in each group were selected based on age, gender, walking status, nursing home residency, delays in surgery, ASA score, and the Charlson comorbidity ...

متن کامل

Femoral Perforation after Hemiarthroplasty – Life goes on for 7 years!

INTRODUCTION Femoral perforation after hemiarthroplasty is a known complication. In cases with cemented hemiarthroplasty the recommendation is to leave the implant till it requires revision while for uncemented hemiarthroplasty early revision is recommended. CASE REPORT We present a case of perforation of lateral femoral cortex after Autin Moore hemiarthroplasty.. The patient reported a swell...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 14 3  شماره 

صفحات  -

تاریخ انتشار 2006