Effectiveness of Inspiratory Termination Synchrony with Automatic Cycling During Noninvasive Pressure Support Ventilation

نویسندگان

  • Yuqing Chen
  • Kewen Cheng
  • Xin Zhou
چکیده

BACKGROUND Pressure support ventilation (PSV) is a standard method for non-invasive home ventilation. A bench study was designed to compare the effectiveness of patient-ventilator inspiratory termination synchronization with automated and conventional triggering in various respiratory mechanics models. MATERIAL AND METHODS Two ventilators, the Respironics V60 and Curative Flexo ST 30, connected to a Hans Rudolph Series 1101 lung simulator, were evaluated using settings that simulate lung mechanics in patients with chronic obstructive pulmonary disease (COPD), acute respiratory distress syndrome (ARDS), or normal lungs. Ventilators were operated with automated (Auto-Trak) or conventional high-, moderate-, and low-sensitivity flow-cycling software algorithms, 5 cmH2O or 15 cmH2O pressure support, 5 cmH2O positive end-expiratory pressure (PEEP), and an air leak of 25-28 L/min. RESULTS Both ventilators adapted to the system leak without requiring adjustment of triggering settings. In all simulated lung conditions, automated cycling resulted in shorter triggering delay times (<100 ms) and lower triggering pressure-time product (PTPt) values. Tidal volumes (VT) increased with lower conventional cycling sensitivity level. In the COPD model, automated cycling had higher leak volumes and shorter cycling delay times than in conventional cycling. Asynchronous events were rare. Inspiratory time (Tinsp), peak expiratory flow (PEF), and cycling off delay time (Cdelay) increased as a result of reduction in conventional cycling sensitivity level. In the ARDS and normal adult lung models, premature cycling was frequent at the high-sensitive cycling level. CONCLUSIONS Overall, the Auto-Trak protocol showed better patient-machine cycling synchronization than conventional triggering. This was evident by shorter triggering time delays and lower PTPt.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patient-Ventilator Interaction During Noninvasive Ventilation in Simulated COPD.

BACKGROUND During noninvasive ventilation (NIV) of COPD patients, delayed off-cycling of pressure support can cause patient ventilator mismatch and NIV failure. This systematic experimental study analyzes the effects of varying cycling criteria on patient-ventilator interaction. METHODS A lung simulator with COPD settings was connected to an ICU ventilator via helmet or face mask. Cycling was...

متن کامل

Effect of an automatic triggering and cycling system on comfort and patient-ventilator synchrony during pressure support ventilation.

BACKGROUND The digital Auto-Trak™ system is a technology capable of automatically adjusting the triggering and cycling mechanisms during pressure support ventilation (PSV). OBJECTIVE To compare Auto-Trak with conventional settings in terms of patient-ventilator synchrony and discomfort. METHODS Twelve healthy volunteers underwent PSV via the mouth by breathing through an endotracheal tube. ...

متن کامل

Influence of different interfaces on synchrony during pressure support ventilation in a pediatric setting: a bench study.

BACKGROUND In adults and children, patient-ventilator synchrony is strongly dependent on both the ventilator settings and interface used in applying positive pressure to the airway. The aim of this bench study was to determine whether different interfaces and ventilator settings may influence patient-ventilator interaction in pediatric models of normal and mixed obstructive and restrictive resp...

متن کامل

Waiting to Exhale: Optimizing Noninvasive Synchrony in COPD?

Noninvasive ventilation (NIV) has become a widely used modality for many types of respiratory conditions. Some advantages of NIV include lower sedation requirement, preservation of cough and pulmonary clearance, and reduced frequency of ventilator-associated pneumonia.1 NIV has been used successfully in patients with cardiogenic pulmonary edema.2-4 It has been shown to decrease intubation durat...

متن کامل

Patient-ventilator asynchrony during noninvasive pressure support ventilation and neurally adjusted ventilatory assist in infants and children*.

OBJECTIVES To document the prevalence of asynchrony events during noninvasive ventilation in pressure support in infants and in children and to compare the results with neurally adjusted ventilatory assist. DESIGN Prospective randomized cross-over study in children undergoing noninvasive ventilation. SETTING The study was performed in a PICU. PATIENTS From 4 weeks to 5 years. INTERVENTI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2016