Results of ulnar shortening osteotomy with a new plate compression system.

نویسندگان

  • Sonya M Clark
  • William B Geissler
چکیده

PURPOSE The gold standard for treatment of ulnar impaction has become ulnar shortening osteotomy. Previous reports in the literature have shown not only good results with relief of ulnar-sided wrist pain but also significant nonunion rates and painful hardware necessitating further surgery and potentially, metal removal. The purpose of this paper is to review the success rate of ulnar shortening osteotomy utilizing a low profile compression plate designed specifically for ulnar shortening osteotomy. METHODS Ninety-three patients with ulnar abutment syndrome underwent ulnar shortening osteotomy with the low profile osteotomy plate. There were 47 males and 46 females. The Acumed's ulnar shortening system was utilized in all cases. The patients were evaluated for pain, range of motion, grip strength, return to work, time to union, and hardware removal. The patients' results were validated using the Mayo Wrist Score. RESULTS There was a 100 % union rate in the 93 patients. There were no nonunions or delayed unions, or any hardware removal. All patients noted an improvement in their ulnar-sided wrist pain. Utilizing the Mayo wrist classification, the average postoperative score was 84.5. The average preoperative Mayo score was 49.4, for an average increase of 35.1 points. CONCLUSION The Acumed's low-contact plate designed specifically for ulnar shortening osteotomy demonstrated 100 % union rate and no implant removal in our series. This is the largest study to our knowledge of a series of ulnar shortening osteotomies and successful healing without the removal of any implants. Furthermore, the specifically designed ulnar shortening osteotomy plate significantly simplifies the procedure for the surgeon and improves patient outcomes with relief of ulnar-sided wrist pain.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ulna shortening osteotomy using a compression device.

PURPOSE To report the functional and radiographic outcomes of a cohort of patients treated for ulnar impaction syndrome with a single technique of ulnar shortening osteotomy. METHOD We performed ulnar shortening osteotomy on 18 consecutive patients over a 10-year period by using an oblique osteotomy and compression plating technique with an AO compression device (Synthes, Paoli, PA). There we...

متن کامل

Patient-related factors influencing ulnar-shortening osteotomy outcomes using the trimed dynamic compression plate.

Ulnocarpal impingement can be surgically managed with various shortening osteotomy techniques. The purpose of this study was to retrospectively examine the outcomes of the ulnar-shortening osteotomy technique using the Trimed dynamic compression plate (Valencia, California) and to determine whether results vary among patient-related factors, including smoking status, occupation, preoperative di...

متن کامل

Stacked-blade, single-cut, ulnar-shortening osteotomy.

The authors reviewed a 10-year consecutive series of ulnar-shortening osteotomies using a freehand, single oblique cut with 2 or 3 stacked saw blades. Twenty-one patients (23 wrists) with chronic ulnar impaction syndrome (mean age, 45 years; range, 16 to 73 years) demonstrated an average preoperative ulnar variance of +2.1 mm (range, 0.0 to 4.0 mm). An oblique osteotomy was performed in the dis...

متن کامل

Variables Prognostic for Delayed Union and Nonunion Following Ulnar Shortening Fixed With a Dedicated Osteotomy Plate.

PURPOSE To examine potential risk factors for the development of delayed or nonunion following elective ulnar shortening osteotomy using a dedicated osteotomy plating system. METHODS We performed a retrospective review of all patients who underwent elective ulnar shortening using the TriMed single osteotomy dynamic compression plating system by 1 of 2 fellowship-trained hand surgeons over a 5...

متن کامل

Step-cut distal ulnar-shortening osteotomy.

PURPOSE Several techniques for ulnar-shortening osteotomies have been described in recent years, reflecting the difficulties that sometimes are encountered in what seems to be a relatively simple procedure. We describe the use of a simple step-cut ulnar-shortening osteotomy stabilized with a lag screw and a palmarly placed 3.5-mm neutralization plate. METHODS Twenty-nine patients had the surg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hand

دوره 7 3  شماره 

صفحات  -

تاریخ انتشار 2012