Silicon nitride for total hip replacements
نویسنده
چکیده
Pettersson, M. 2015. Silicon nitride for total hip replacements. Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology 1242. 53 pp. Uppsala: Acta Universitatis Upsaliensis. ISBN 978-91-554-9211-3. For more than 50 years total hip replacements have been a common and successful procedure to increase patient mobility and quality of life. The 10-year implant survival rate is 97.8%. However, for longer implantation times there are limitations linked to the negative biological response to wear and corrosion products from the currently used biomaterials. In this thesis silicon nitride (SiNx) coatings were evaluated for use in total hip replacements, on the articulating bearing surface and modular taper connections. Homogeneous, dense SiNx coatings were deposited using reactive high power impulse magnetron sputtering (HiPIMS) up to a thickness of 8 μm. The N/Si atomic ratios ranged from 0.3 to 1.1 and the coatings showed a low surface roughness. The wear rate of a SiNx coated cobalt chromium molybdenum alloy (CoCrMo) was similar to that of bulk Si3N4, and less than one 46 of uncoated CoCrMo, an alloy that is commonly used in joint replacements. Wear debris generated from SiNx coatings was round in shape, with a mean size of 40 nm, and ranged between 10 and 500 nm. Model particles, similar in size and shape as the wear debris, were soluble in simulated body fluid. The dissolution rate was higher than the expected rate of debris generation. Along with the size of the debris, which is not in the critical range for macrophage activation, this dissolution may limit negative biological reactions. The SiNx coatings also dissolved in simulated body fluid. The coating with the highest N/Si ratio exhibited the lowest dissolution rate, of 0.2 to 0.4 nm/ day, while CoCrMo under the same condition dissolved at a rate of 0.7 to 1.2 nm/day. SiNxcoated CoCrMo exhibited a reduced release of Co, Cr and Mo ions into the solution by two orders of magnitude, compared to uncoated CoCrMo. Si3N4 evaluated under micro-displacement in a corrosive environment, replicating the modular taper, showed a lower corrosion current compared to common biomedical alloys. SiNx coatings may also act beneficially to reduce issues associated with this type of contact. SiNx coatings have shown several properties in a laboratory environment that are hypothesised to increase the longevity of joint replacements. The promising results encourage further evaluation closer to the clinical application of total hip replacements, in particular in the articulating bearing surface and in modular tapers.
منابع مشابه
The Rationale for Silicon Nitride Bearings in Orthopaedic Applications
The history of silicon nitride (Si3N4) has been described previously; detailed analyses of particles of meteroritic rock have been shown to contain silicon nitride crystals, suggesting that this material exists naturally in the galaxy.1 Synthetic Si3N4 was probably developed by Deville and Wöhler in 1859. Commercial interest in this material increased in the 1950s, as the material properties of...
متن کاملEvaluation of silicon nitride as a wear resistant and resorbable alternative for total hip joint replacement
Many of the failures of total joint replacements are related to tribology, i.e., wear of the cup, head and liner. Accumulation of wear particles at the implants can be linked to osteolysis which leads to bone loss and in the end aseptic implant loosening. Therefore it is highly desirable to reduce the generation of wear particles from the implant surfaces. Silicon nitride (Si(3)N(4)) has shown ...
متن کاملMechanical and tribological behavior of silicon nitride and silicon carbon nitride coatings for total joint replacements.
Total joint replacements currently have relatively high success rates at 10-15 years; however, increasing ageing and an active population places higher demands on the longevity of the implants. A wear resistant configuration with wear particles that resorb in vivo can potentially increase the lifetime of an implant. In this study, silicon nitride (SixNy) and silicon carbon nitride (SixCyNz) coa...
متن کاملA Single Femoral Component for All Total Hip Replacements Performed by a Trust? Does This Affect Early Clinical and Radiological Outcomes?
Background: Hospitals may be under pressure to implement cost saving strategies regarding prosthesis choice. Thismay involve the use of components which are not the first preference of individual surgeons, or those they have littleexperience with. We aim to examine the effect of standardizing the type of femoral stem used in a single trust, anddetermine whether this is safe practice, particular...
متن کاملFuture Bearing Surfaces in Total Hip Arthroplasty
One of the most important issues in the modern total hip arthroplasty (THA) is the bearing surface. Extensive research on bearing surfaces is being conducted to seek an ideal bearing surface for THA. The ideal bearing surface for THA should have superior wear characteristics and should be durable, bio-inert, cost-effective, and easy to implant. However, bearing surfaces that are currently being...
متن کامل