Effective Pattern Intensity Artifacts Treatment for Electron Diffractive Imaging

نویسندگان

  • Francesco Scattarella
  • Liberato De Caro
  • Dritan Siliqi
  • Elvio Carlino
چکیده

We present a method to treat spurious intensities in electron diffraction experiments. Coherent electron diffraction imaging requires proper data reduction before the application of phase retrieval algorithms. The presence of spurious intensities in the electron diffraction patterns makes the data reduction complicated and time consuming and jeopardizes the application of mathematical constraints to maximize the information that can be extracted from the experimental data. Here we show how the experimental diffraction patterns can be treated to remove the unwanted artifacts without corrupting the genuine intensities scattered by the specimen. The resulting diffraction patterns are suitable for the application of further processes and constraints aimed at deriving fundamental structural information by applying phase retrieval algorithms or other approaches capable of deriving quantitative atomic resolution information about the specimen structure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Facing the phase problem in Coherent Diffractive Imaging via Memetic Algorithms

Coherent Diffractive Imaging is a lensless technique that allows imaging of matter at a spatial resolution not limited by lens aberrations. This technique exploits the measured diffraction pattern of a coherent beam scattered by periodic and non-periodic objects to retrieve spatial information. The diffracted intensity, for weak-scattering objects, is proportional to the modulus of the Fourier ...

متن کامل

Diffractive imaging based on a multipinhole plate.

We report on a noniterative method for coherent diffractive imaging based on a specially designed multipinhole (MP) plate. We demonstrated that the complex amplitude of the wavefront penetrating through an MP plate inserted between the specimen and the detector plane can be directly extracted from the Fourier transform of a single far-field diffraction intensity pattern without need of any iter...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

High-resolution three-dimensional partially coherent diffraction imaging.

The wave properties of light, particularly its coherence, are responsible for interference effects, which can be exploited in powerful imaging applications. Coherent diffractive imaging relies heavily on coherence and has recently experienced rapid growth. Coherent diffractive imaging recovers an object from its diffraction pattern by computational phasing with the potential of wavelength-limit...

متن کامل

A feasibility study on the use of MV-CBCT images for urgent palliative treatment planning

Introduction: The application of 3D volumetric imaging modalities in treatment planning of radiation therapy can provide more precisely define tumor localization, and computed tomography (CT) is the most common accepted method for treatment planning. Given the lack of a CT scanner stationed in all radiotherapy departments and equipping most of the medical linear accelerators wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017