Simultaneous versus video counting of coughs in hypertonic cough challenges
نویسندگان
چکیده
BACKGROUND The coughs occurring during cough provocation tests are usually counted at the same time when the test is being conducted, i.e., simultaneously. It is unknown whether cough counting from video recording might increase the accuracy of the cough counting. During recent years, cough challenges with hypertonic aerosols have been introduced. They often provoke very frequent coughing which may complicate the simultaneous cough counting. OBJECTIVE To assess whether cough counting from video recording is superior to simultaneous cough counting in two different hypertonic cough challenges. METHODS The analysis includes 82 hypertonic saline challenges performed on 66 subjects, providing 1984 observation minutes with both simultaneous and video cough counting. The cough sensitivity was expressed as the osmolality to provoke 15 cumulative coughs (CUM15). The analysis also includes 136 hypertonic histamine challenges performed on 114 subjects providing 5373 observation minutes with both simultaneous and video counting. The cough sensitivity was expressed as the cumulative number of coughs divided by the final histamine concentration administered (CCR). This challenge involved several additional measurements to cough counting. RESULTS For the saline challenge, the mean difference between the counting types was 0.0 coughs per minute with 95% limits of agreement of -1.2 to 1.2 coughs per minute. For the hypertonic histamine challenge the respective figures were 0.3 (-1.9 to 2.5) coughs per minute. At high coughing frequency the video counts tended to outnumber the simultaneous counts. The counting type had no effect on the hypertonic saline CUM15 and only a marginal effect on its repeatability. On the contrary, video counting resulted to significantly higher hypertonic histamine CCR values than simultaneous counting (p < 0.001). CONCLUSION The agreement between simultaneous and video counting of coughs is generally good. However, as the coughing frequency increases, simultaneous counting may miss coughs, especially if the nurse has to share his/her attention to several activities simultaneously. Video recording is advisable for the hypertonic histamine challenge but unnecessary for the hypertonic saline challenge. To ensure reliable simultaneous cough counting, cough provocation tests should be performed in a quiet environment, applying as little unnecessary equipment and measurements as possible.
منابع مشابه
Establishing a gold standard for manual cough counting: video versus digital audio recordings
BACKGROUND Manual cough counting is time-consuming and laborious; however it is the standard to which automated cough monitoring devices must be compared. We have compared manual cough counting from video recordings with manual cough counting from digital audio recordings. METHODS We studied 8 patients with chronic cough, overnight in laboratory conditions (diagnoses were 5 asthma, 1 rhinitis...
متن کاملInterpretation of cough provoked by airway challenges.
STUDY OBJECTIVE To analyze the cough response to three airway challenges in order to clarify whether the recording of the provoked coughs would be beneficial in the management of asthma. DESIGN A prospective study. SETTING University hospital. PARTICIPANTS Fifteen healthy subjects, 16 steroid-naïve subjects with asthma, and 16 subjects with steroid-treated asthma. INTERVENTIONS Inhalati...
متن کاملCough response to isocapnic hyperpnoea of dry air and hypertonic saline are interrelated
BACKGROUND Mechanisms behind asthmatic cough are largely unknown. It is known that hyperosmolar challenges provoke cough in asthmatic but not in the healthy subjects. It has been postulated that isocapnic hyperpnea of dry air (IHDA) and hypertonic aerosols act via similar mechanisms in asthma to cause bronchoconstriction. We investigated whether there is an association between cough response in...
متن کاملThe automatic recognition and counting of cough
BACKGROUND Cough recordings have been undertaken for many years but the analysis of cough frequency and the temporal relation to trigger factors have proven problematic. Because cough is episodic, data collection over many hours is required, along with real-time aural analysis which is equally time-consuming. A method has been developed for the automatic recognition and counting of coughs in so...
متن کاملData reduction for cough studies using distribution of audio frequency content
UNLABELLED BACKGROUND Recent studies suggest that objectively quantifying coughing in audio recordings offers a novel means to understand coughing and assess treatments. Currently, manual cough counting is the most accurate method for quantifying coughing. However, the demand of manually counting cough records is substantial, demonstrating a need to reduce record lengths prior to counting wh...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cough (London, England)
دوره 4 شماره
صفحات -
تاریخ انتشار 2008