Outcomes of 140 consecutive cases of 25-gauge transconjunctival surgery for posterior segment disease.
نویسندگان
چکیده
PURPOSE To evaluate the safety and efficacy of 25-gauge instrumentation for a variety of vitreoretinal conditions on previously nonvitrectomized eyes. DESIGN Single-center, retrospective, interventional case series. PARTICIPANTS One-hundred forty eyes of 140 patients were evaluated at the Doheny Retina Institute from July 2002 to July 2003. INTERVENTION All patients underwent surgical procedures using the Millennium 25-gauge Transconjunctival Standard Vitrectomy system. Twenty eyes (14.3%) underwent procedures without vitrectomy. MAIN OUTCOME MEASURES Postoperative visual acuity (VA), intraocular pressure, surgical time, postoperative inflammation, complications, and number of sutured sites. RESULTS No intraoperative complications were noted. No cases required conversion to 20-gauge machines. Ten cases (7.1%) involved single-site sclerotomy suture placement due to bleb formation at the conclusion of the procedure, but 5 of these entry sites were enlarged to facilitate larger instrumentation for tissue manipulation. Median VA improved from 20/250 (logarithm of the minimum angle of resolution, 1.08+/-0.47) preoperatively to 20/60 (0.47+/-0.30) (P<0.0001) at final visit. Mean follow-up was 33.8+/-9.7 weeks, and all eyes were observed for a minimum of 12 weeks. Mean total surgical time was 17.4+/-6.9 minutes. Intraocular pressures remained stable throughout the postoperative course. Five eyes (3.8%) presented on day 1 with shallow choroidal detachments, but all resolved by day 7, and none required volume infusion during the postoperative period. All but one of these cases was within the first 50 procedures performed. No detectable inflammation was noted in any eyes by 4 weeks postoperatively. No case of retinal detachment or endophthalmitis was recorded. CONCLUSIONS Transconjunctival surgery using 25-gauge instrumentation may hasten postoperative recovery by decreasing overall surgical time and postoperative inflammation. Procedures requiring minimal intraocular manipulation did not require sutures and, thus, may be better suited for this surgical modality.
منابع مشابه
Comparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy
BACKGROUND To assess the rate and type of retinal break formation in patients undergoing 23 gauge transconjunctival vitrectomy surgery for complications of proliferative diabetic retinopathy compared with 20 gauge vitrectomy surgery. METHODS Retrospective case notes review of two consecutive series of patients who had primary pars plana vitrectomy for complications of proliferative diabetic r...
متن کاملSurgical outcomes of 25-gauge transconjunctival vitrectomy combined with cataract surgery for vitreoretinal diseases.
INTRODUCTION To report surgical outcomes of 25-gauge transconjunctival vitrectomy combined with cataract surgery for the management of a variety of vitreoretinal diseases. MATERIALS AND METHODS A retrospective, interventional case study was conducted. Chart review of a consecutive series of 150 eyes of 144 patients who underwent 25-gauge vitrectomy combined with phacoemulsification and intrao...
متن کاملOutcomes of 27 Gauge Microincision Vitrectomy Surgery for Posterior Segment Disease.
PURPOSE To report the initial experience, clinical outcomes, and safety profile of 27 gauge pars plana vitrectomy (PPV) in eyes with posterior segment disease. DESIGN Multicenter, retrospective, interventional case series. METHODS setting: Private practice and tertiary care settings. STUDY POPULATION Eyes undergoing 27 gauge PPV for a vitreoretinal surgery indication. INTERVENTION Three...
متن کاملTransconjunctival sutureless 25-gauge vitrectomy with newly designed microcannulas.
AIM To evaluate the usefulness of the newly designed 25-gauge (25-G) microcannula for transconjunctival sutureless vitrectomy (TSV). METHODS 25-G TSV was performed on 20 consecutive eyes with the newly designed 25-G microcannulas. We studied usefulness, intraoperative and postoperative complications in these cases. RESULTS No complications were recognized during surgery. Postoperative compl...
متن کاملComparison of Efficacy and Safety between Transconjunctival 23-Gauge and Conventional 20-Gauge Vitrectomy Systems in Macular Surgery
PURPOSE To compare the efficacy and safety of 23-gauge transconjunctival vitrectomy with the conventional 20-gauge method in idiopathic epiretinal membrane and macular hole surgery. METHODS Sixty-one consecutive patients undergoing vitrectomy for idiopathic epiretinal membrane and macular hole were recruited to either 20- or 23-gauge vitrectomy groups and prospectively evaluated. Surgical suc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmology
دوره 112 5 شماره
صفحات -
تاریخ انتشار 2005