Repeatability and bronchodilator reversibility of lung function in young children.
نویسندگان
چکیده
Knowledge of short- and longer-term repeatability of lung function in health and disease is essential to determine bronchodilator reversibility thresholds and to recognise if changes in lung function represent disease progression, therapeutic intervention or normal variability. Multiple-breath washout indices (lung clearance index, conductive ventilation inhomogeneity (Scond)) and specific airway resistance (sRaw) were measured in healthy children and stable wheezers. Measurements were performed at baseline and after 20 min without intervention to assess repeatability and determine bronchodilator reversibility thresholds. Bronchodilator reversibility was assessed by repeating baseline measurements 20 min after inhaled salbutamol. 28 healthy controls, mean±sd age 6.1±0.7 years and 62 wheezers 5.4±0.6 years were tested. Baseline variability in multiple-breath washout indices and sRaw was not significantly different between wheezers and healthy controls. Significant bronchodilator reversibility was only observed in wheezers for Scond (16%), but in both wheezers (37%) and healthy controls (20%) for sRaw. Some wheezers and healthy controls demonstrated increases in multiple-breath washout indices post-bronchodilator. Lung clearance index and sRaw demonstrate low baseline variability in healthy and diseased subjects. Neither multiple-breath washout indices nor sRaw are ideal for assessing bronchodilator reversibility in young children with stable wheeze. These findings will help to interpret the effect of therapeutic interventions in children with respiratory diseases.
منابع مشابه
Comparative analysis of the bronchodilator response measured by impulse oscillometry (IOS), spirometry and body plethysmography in asthmatic children.
BACKGROUND Asthma is common among young children. The assessment of respiratory resistance by the impulse oscillometry system (IOS), based on the superimposition of respiratory flow by short-time impulses, requires no patient active collaboration. AIM We evaluated the baseline repeatability and bronchodilator response of IOS indices in preschool children, their correlation with spirometry and...
متن کاملMeasurement of airway resistance using the interrupter technique in preschool children in the ambulatory setting.
This study describes the feasibility, repeatability, and interrater reliability of the measurement of airway resistance by the interrupter technique (Rint) in children 2-5 yrs of age, and examines whether reversibility to bronchodilator can be demonstrated in wheezy children. The mean of six Rint values was taken as a measurement. If subjects could complete one measurement and then a second 15 ...
متن کاملForced expiratory flows' contribution to lung function interpretation in schoolchildren.
Forced expiratory flow (FEF) at low lung volumes are supposed to be better at detecting lung-function impairment in asthmatic children than a forced volume. The aim of this study was to examine whether FEF results could modify the interpretation of baseline and post-bronchodilator spirometry in asthmatic schoolchildren in whom forced expiratory volumes are within the normal range. Spirometry, w...
متن کاملDiagnosis of asthma in symptomatic children based on measures of lung function: an analysis of data from a population-based birth cohort study
BACKGROUND Concerns have been expressed about asthma overdiagnosis. The UK National Institute of Health and Care Excellence (NICE) proposed a new diagnostic algorithm applying four lung function measures sequentially (ratio of forced expiratory volume in 1 s [FEV1] to forced vital capacity [FVC] <70%, bronchodilator reversibility ≥12%, fractional exhaled nitric oxide [FeNO] ≥35 parts per billio...
متن کاملBronchodilator responsiveness using spirometry in healthy and asthmatic preschool children.
OBJECTIVE To assess repeatability and reproducibility of spirometry measurements, and bronchodilator responsiveness (BDR), in healthy 3-6-year-old preschool children and those with asthma. DESIGN Spirometry was performed before and 20 minutes after administering either inhaled placebo (for repeatability) or 400 μg salbutamol (for BDR) on two separate occasions (reproducibility) 3-23 days apar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 42 1 شماره
صفحات -
تاریخ انتشار 2013