Vacuum-assisted venous drainage: to air or not to air, that is the question. Has the bubble burst?

نویسنده

  • Timothy W Willcox
چکیده

Assisted venous drainage is a recent development in cardiopulmonary bypass (CPB) and was introduced to overcome limitations in achieving adequate blood flow through small diameter cannulas used in minimally invasive surgery. The more common application, vacuum assisted venous drainage (VAVD) is now widely used in both adult and pediatric CPB. During a clinical investigation into pharmacological cerebral protection at Green Lane Hospital, we repeatedly observed evidence of emboli in the right common carotid artery following both entrainment of air into the venous line, and also, reductions in the blood level of the hard-shell venous reservior. We subsequently embarked upon a series of in vitro experiments designed to identify sources of emboli from the CPB circuit, and to evaluate the ability of CPB circuit components to remove air entrained into the venous line under conditions of both gravity and vacuum assisted venous drainage. Initial experiments revealed design features of certain hard-shell venous reservoirs that generated gaseous emboli. In further studies using adult circuits, entrainment of air into the venous line under conditions of conventional gravity venous drainage resulted in emboli distal to the arterial filter. When these studies were repeated using VAVD, arterial line emboli increased eight to tenfold. Initial experiments with a pediatric circuit showed similar findings. Cerebral emboli during CPB have been positively correlated with increasing neurocognitive deficits. The application of VAVD has been employed clinically without any significant redesign of the components of the CPB circuit. While VAVD may be efficacious in certain scenarios, a thorough understanding of its influence on CPB is essential. Advantages must be balanced against potential hazards. The safe use of VAVD necessitates refinement of perfusion techniques, judicious choice of application, and further development of the CPB circuit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assisted venous drainage, venous air, and gaseous microemboli transmission into the arterial line: an in-vitro study.

The objective of this study was to examine the interaction of cardiopulmonary bypass venous air with assisted venous drainage, focusing on its production of gaseous microemboli in the arterial line. An in-vitro recirculating cardiopulmonary bypass circuit containing fresh whole bovine blood was monitored with a pulsed-doppler microbubble detector. Air of specific amounts was injected into the v...

متن کامل

Vacuum-assisted venous drainage and gaseous microemboli in cardiopulmonary bypass.

When conventional gravity siphon venous drainage cannot achieve satisfactory venous drainage during minimally invasive cardiac and neonatal surgeries, assisted venous drainage techniques are needed to ensure adequate flow. One assisted venous drainage technique, vacuum-assisted venous drainage (VAVD), the aid of a vacuum in the venous reservoir, is now widely used to augment venous drainage dur...

متن کامل

Experimental Study of Heat Transfer Rate in a Shell and Tube Heat Exchanger with Air Bubble Injection (TECHNICAL NOTE)

Shell and tube heat exchangers are widely being used in many of industrial and power engineering applications. Different techniques have been employed in order to enhance the performance of the heat exchanger. Air bubble injection is one method to increase the turbulence of the flowing fluids which in turn enhance the heat transfer performance. Injecting air bubbles is one of the promising tech...

متن کامل

Heat transfer enhancement due to air bubble injection into a horizontal double pipe heat exchanger

If an air flow is injected into a liquid fluid, many ambulant air bubbles are formed inside the fluid. Air bubbles move inside the liquid fluid because of the buoyancy force, and the mobility of these air bubbles makes sizable commixture and turbulence inside the fluid. This mechanism was employed to enhance the heat transfer rate of a horizontal double pipe heat exchanger in this paper. Howeve...

متن کامل

The influence of vacuum assisted drainage on arterial line emboli.

We read with interest the article by Jones and colleagues entitled “How Effective are Cardiopulmonary Bypass Circuits at Removing Gaseous Microemboli” (1). Their invariable detection of gaseous microemboli (GME) distal to the cardiopulmonary bypass (CPB) arterial line filter after entrainment of air to the venous line is in complete agreement with our original report of the same phenomenon (2)....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید