A randomized study of the effect of patient positioning on setup reproducibility and dose distribution to organs at risk in radiotherapy of rectal cancer patients

نویسندگان

  • Trude C. Frøseth
  • Trond Strickert
  • Kjersti S. Solli
  • Øyvind Salvesen
  • Gunilla Frykholm
  • Randi J. Reidunsdatter
چکیده

BACKGROUND The patient positioning in pelvic radiotherapy (RT) should be decided based on both reproducibility and on which position that yields the lowest radiation dose to the organs at risk (OAR), and thereby less side effects to patients. The present randomized study aimed to evaluate the influence of patient positioning on setup reproducibility and dose distribution to OAR in rectal cancer patients. METHODS Ninety-one patients were randomized into receiving RT in either supine or prone position. The recruitment period was from 2005 to 2008. Position deviations were derived from electronic portal image registrations, and setup errors were defined as deviations between the expected and the actual position of bony landmarks. Setup deviations were expressed into three table shift values (∆x, ∆y, ∆z) from which the deviation vector [Formula: see text] were calculated. The estimated lengths of [Formula: see text] defined the main outcome and were compared between prone and supine positions using linear mixed model statistics. The mean volume of each 5 Gy increments between 5 and 45 Gy was calculated for the small bowel and the total bowel, and the dose volumes were compared between prone and supine position. RESULTS AND CONCLUSION Data from 83 patients was evaluable. The mean [Formula: see text] was 5.8 mm in supine position and 7.1 mm in prone position (p = 0.024), hence the reproducibility was significantly superior in supine position. However, the difference was marginal and may have borderline clinical importance. The irradiated volumes of the small bowel and the total bowel were largest in the supine position for all dose levels, but none of those were significantly different. The patient positioning in RT of rectal cancer patients may therefore be decided based on other factors such as the most comfortable position for the patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compare the organs at risk in breast-conserving three- dimensional conformal radiotherapy (3D-CRT) based on patient\'s breast size

Introduction: Breast cancer is the most common cancer among women. Radiotherapy plays an important role in the treatment of breast cancer and essential part of the standard treatment after breast-conserving surgery, routinely done to eliminate the microscopic residual cancer. The heart and lungs are one of the most important organs at risk of breast cancer radiotherapy that th...

متن کامل

The effect of Rectal Retractor, a rectal protector on rectal dose in radical prostate radiotherapy

Introduction: The close proximity of the rectum tissue to the prostate gland results in rectal toxicity during prostate radiotherapy. Rectal Retractor (RR) is a rectal displacement technique that inserts into the rectum, as a result, the lateral and dorsal part of the rectal wall push away from high dose areas. The aim of this study was to investigate the dosimetric consequence...

متن کامل

Compare the organs at risk in breast-conserving three- dimensional conformal radiotherapy (3D-CRT) based on patient's breast size

Introduction: Breast cancer is the most common cancer among women. Radiotherapy plays an important role in the treatment of breast cancer and essential part of the standard treatment after breast-conserving surgery, routinely done to eliminate the microscopic residual cancer. The heart and lungs are one of the most important organs at risk of breast cancer radiotherapy that th...

متن کامل

Analysis of Hip Joint Dose in Prostate Cancer Radiation Therapy: A Dosimetric Comparison of Treatment Plans

Background and purpose: Radiation therapy as a part of cancer treatment is used in almost 50-60% of involved cases. In prostate cancer radiation therapy, a large volume of pelvis is irradiated, so, it is necessary to preserve sensitive organs around the treatment area, especially rectum and bladder. In this study, some dosimetric parameters such as minimum dose (Dmin), maximum dose (Dmax), mean...

متن کامل

Dosimetric Effects of Rotational Setup Error in Volumetric Modulated Arc Radiotherapy on Brain Tumor Patients

Introduction: This study examined the dosimetric effects based on the rotational setup error to correct patient setup errors occur during volumetric modulated arc radiotherapy (VMAT) for brain tumor patients. Material and Methods: This study included 1129 cases of cone beam computed tomography (CBCT) images obtained from 46 brain tumor patients, who experienced VMAT and used the 6DoF (degree o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015