Tomography without Rays

نویسندگان

  • CHARLES J. AMMON
  • JOHN E. VIDALE
چکیده

We present two new techniques for the inversion of first-arrival times to estimate velocity structure. These travel-time inversion techniques are unique in that they do not require the calculation of ray paths. First-arrival times are calculated using a finite-difference scheme that iteratively solves the eikonal equations for the position of the wavefront. The first inversion technique is a direct extension of linearized waveform inversion schemes. The nonlinear relationship between the observed first-arrival times and the model slowness is linearized using a Taylor series expansion and a solution is found by iteration. For a series of two-dimensional numerical tests, with and without random noise, this travel-time inversion procedure accurately reconstructed the synthetic test models. This iterative inversion procedure converges quite rapidly and remains stable with further iteration. The second inversion technique is an application of simulated annealing to travel-time topography. The annealing algorithm is a randomized search through model space that can be shown to converge to a global minimum in well-posed problems. Our tests of simulated annealing travel-time topography indicate that, in the presence of less than ideal ray coverage, significant artifacts may be introduced into the solution. The linearized inversion scheme outperforms the nonlinear simulated annealing approach and is our choice for travel-time inversion problems. Both techniques are applicable to a variety of seismic problems including earthquake travel-time tomography, reflection, refraction/wide-angle reflection, borehole, and surface-wave phase-velocity tomography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners

Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...

متن کامل

Reliability of Postoperative Radiographies in Ankle Fractures

Background: The accuracy of reduction of ankle fractures using postoperative plain radiographies (x-ray) remainswidely controversial. Some authors have demonstrated that postoperative computed tomography (CT) scan can beuseful for these patients. In current study, the efficacy of x-rays after fixation of ankle fractures was investigated basedon the CT scan findings.Metho...

متن کامل

Isolated Unilateral Absence of a Pulmonary Artery A Case Report

Unilateral absence of a pulmonary artery (UAPA) is a rare pulmonary vascular anomaly that is usually associated with other cardiac anomalies. We report a 9-year-old female diagnosed with isolated unilateral absence of the left pulmonary artery and a right aortic arch but without other cardiac anomalies. The only symptoms the patient had were recurrent respiratory tract infections. The chest x-r...

متن کامل

Atypical Radiological Findings in Patients with Hydatid Cysts of the Lung, Study of 1024 Cases

Introduction : The objective of this study was to give a description of the most prominent atypical radiological presentations of lung hydatidosis. Materials and methods: All patients diagnosed with pulmonary hydatidosis by surgical exploration were included in this study. Standard chest roentgenogram and computed tomography CT) were evaluated before surgery for lung cysts or unknown lesions. R...

متن کامل

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

متن کامل

Investigation of I.C. samples using X-ray computer tomography

Structure complexity combined with high integration level in microelectronic industry is making the analysis more and more difficult. Non Destructive Analysis of either new semiconductor generation (e.g BGA, Flipchip) or double-sided printed circuit boards, is becoming very difficult as most of the critical structure features are hidden. Although 2D-X-rays inspection is still the most popular n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005