Laparoscopic Retrieval of Intrauterine Device Perforating the Sigmoid Colon

نویسندگان

  • Angie R. Taras
  • Jedediah A. Kaufman
چکیده

INTRODUCTION The intrauterine device (IUD) is a well-tolerated, widely used contraceptive. A major but infrequent complication of the IUD is perforation of the uterus or cervix and migration of the device into the abdomen. Our case of laparoscopic retrieval of an IUD perforating the sigmoid colon illustrates this rare complication. METHODS A 36-year-old woman with a history of IUD placement 4 years earlier presented with complaints of abdominal pain and bright red blood per rectum. She had conceived 9 months after IUD placement and suffered a spontaneous abortion requiring an evacuation of the retained products of conception. At presentation, she was afebrile with normal vital signs. Physical examination was significant for tenderness to palpation over the left lower quadrant. RESULTS Computed tomography (CT) scans of the abdomen and pelvis showed a foreign body through the wall of the uterus and entering the colon. Colonoscopy revealed an IUD penetrating the sigmoid wall, and multiple failed attempts were made to remove the IUD colonoscopically. Diagnostic laparoscopy was performed that revealed an IUD perforating the uterus and entering the sigmoid. The IUD was manipulated free and removed, and a suture closed the sigmoid defect. The patient was discharged home on the first postoperative day without complication. CONCLUSIONS The IUD is one of the most effective, safe, and economic contraceptive methods. Uterine perforation and intraperitoneal translocation is an unusual complication of an IUD. Perforation of hollow viscous is likely even less common. Confirmation of a "missing" IUD is mandatory if pregnancy occurs after IUD placement. Removal of a translocated IUD is recommended, and operative laparoscopy is the preferred method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laparoscopic Removal of an Intrauterine Device Following Colon Perforation

BACKGROUND Intrauterine device (IUD) migration and colon perforation is a rare but serious complication occurring sometimes years after insertion. Laparoscopic removal of a colon-perforating device is a seldom-used approach. CASE A 35-year-old presented with right upper quadrant (RUQ) abdominal pain one year following intrauterine device (IUD) insertion. Upon vaginal examination, no IUD strin...

متن کامل

Laparoscopic removal of an intrauterine device from the sigmoid colon

Uterine wall perforation which is commonly seen through the posterior wall of the uterus is the most serious complication of an intrauterine device (IUD). We present a case of laparoscopic removal of an IUD from the sigmoid colon in a 31-years-old female who was admitted to hospital with a history of pelvic pain and abnormal vaginal bleeding for one month. The dislocated IUD was removed from th...

متن کامل

Migration of an intrauterine contraceptive device into the sigmoid colon.

We present a case of migrating copper-T intrauterine contraceptive device (IUCD) into the bowel wall at the recto-sigmoid junction, and the colonoscopic retrieval of the device. This case introduces the possibility of safe rectal retrieval of migrating IUCD implanted into the bowel wall.

متن کامل

Laparoscopic Removal of a Copper Intrauterine Device from the Sigmoid Colon

IUD translocation to the sigmoid colon after uterine perforation is a rare but serious event. Removal of the IUD in such a situation has been recommended because of the risk of complication, such as fistula formation and colonic perforation. We present the case of a 43-year-old female with a copper T380A IUD embedded in the sigmoid colon, which was removed with minimally invasive techniques.

متن کامل

Colonoscopic retrieval of migrated copper-T

Intrauterine contraceptive devices have been in use for a long time as family planning measures, one of its complications of perforating the uterus and migrating into the peritoneal cavity is also well known. Retrieval in such cases depends on the location of the migrated intrauterine devices and involves laparotomy or laparoscopy. We present here such a case that migrated partially into the lu...