False Loss of Resistance in Cervical Epidural Injection: The Loss of Resistance Technique Compared with the Epidrum Guidance in Locating Epidural Space.
نویسندگان
چکیده
BACKGROUND Epidural block failures can occur due to a misleading loss of resistance (LOR) signal. OBJECTIVE This study was designed to evaluate the false LOR rate and to determine whether the Epidrum, which is an LOR device for identifying the epidural space, improves the ability to find the epidural space during cervical epidural injection compared the LOR technique. STUDY DESIGN A randomized, single-blind trial. SETTING Single academic medical center. METHODS A total of 150 patients undergoing cervical interlaminar epidural injections at C7-T1 were randomized to receive either the LOR technique with a syringe (group C) or the Epidrum guidance (group E). Fluoroscopic images were used to confirm the accuracy of the needle placement within the epidural space. The rate of misleading epidural signals and adverse effects were recorded and analyzed. RESULTS The false LOR rate was 74.7% for group C, 62.7% for group E, and 68.7% overall. The incidence of false LOR was not significantly different between the 2 groups. Also, the success rate and the rate of true epidural signals were similar between the 2 groups. LIMITATIONS The Epidrum cannot be used to confirm whether the needle has entered the vascular space without fluoroscopy. CONCLUSIONS In this study, we did not find any difference in accuracy between the Epidrum and the LOR technique with a syringe for detecting the cervical epidural space. The overall higher false LOR rate suggests that the combined use of fluoroscopy and LOR technique with a syringe or the Epidrum is necessary to increase the rate of finding the true cervical epidural space. CLINICAL TRIALS REGISTRATION KCT0001333.
منابع مشابه
Comparison of loss of resistance technique between Epidrum® and conventional method for identifying the epidural space
BACKGROUND Epidrum® is a recently developed, air operated, loss of resistance (LOR) device for identifying the epidural space. We investigated the usefulness of Epidrum® by comparing it with the conventional LOR technique for identifying the epidural space. METHODS One hundred eight American Society of Anesthesiologists (ASA) physical status I or II patients between the ages of 17 and 68 year...
متن کاملMethod to Reduce the False-Positive Rate of Loss of Resistance in the Cervical Epidural Region
Background. The cervical epidural space can be detected by the loss of resistance (LOR) technique which is commonly performed using air. However, this technique using air has been associated with a high false-positive LOR rate during cervical interlaminar epidural steroid injections (CIESIs). Objective. We investigated whether the detection of LOR with contrast medium might reduce the false-pos...
متن کاملThe BiP Test: a modified loss of resistance technique for confirming epidural needle placement.
BACKGROUND Correct identification of the epidural space minimizes complications and ensures successful epidural blockade. The loss of resistance technique is the most common technique used for identification of the epidural space. However, sometimes loss of resistance occurs when the needle is not actually in the epidural space. The injection in this instance will result in the medication not b...
متن کاملUltrasonographic Measurement of the Ligamentum Flavum Depth; Is It a Reliable Method to Distinguish True and False Loss of Resistance?
BACKGROUND Previous studies have shown that if performed without radiographic guidance, the loss of resistance (LOR) technique can result in inaccurate needle placement in up to 30% of lumbar epidural blocks. To date, no study has shown the efficacy of measuring the depth of the posterior complex (ligamentum flavum, epidural space, and posterior dura) ultrasonographically to distinguish true an...
متن کاملDelayed Pneumocephalus Following Fluoroscopy Guided Cervical Interlaminar Epidural Steroid Injection: A Rare Complication and Anatomical Considerations
Cervical epidural steroid injection is indicated for radicular symptoms with or without axial neck pain. Complications are rare but can be serious. Here, we report the case of a 54-year-old man with cervical radicular pain who was treated with cervical epidural steroid injection. Injection was administered twice under fluoroscopic guidance with the loss-of-resistance technique using air to conf...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Pain physician
دوره 19 3 شماره
صفحات -
تاریخ انتشار 2016