Effect of expiratory flow limitation on respiratory mechanical impedance: a model study.

نویسندگان

  • R Peslin
  • R Farré
  • M Rotger
  • D Navajas
چکیده

Large phasic variations of respiratory mechanical impedance (Zrs) have been observed during induced expiratory flow limitation (EFL) (M. Vassiliou, R. Peslin, C. Saunier, and C. Duvivier. Eur. Respir. J. 9: 779-786, 1996). To clarify the meaning of Zrs during EFL, we have measured from 5 to 30 Hz the input impedance (Zin) of mechanical analogues of the respiratory system, including flow-limiting elements (FLE) made of easily collapsible rubber tubing. The pressures upstream (Pus) and downstream (Pds) from the FLE were controlled and systematically varied. Maximal flow (Vmax) increased linearly with Pus, was close to the value predicted from wave-speed theory, and was obtained for Pus-Pds of 4-6 hPa. The real part of Zin started increasing abruptly with flow (V) > 85% Vmax and either further increased or suddenly decreased in the vicinity of Vmax. The imaginary part of Zin decreased markedly and suddenly above 95% Vmax. Similar variations of Zin during EFL were seen with an analogue that mimicked the changes of airway transmural pressure during breathing. After pressure and V measurements upstream and downstream from the FLE were combined, the latter was analyzed in terms of a serial (Zs) and a shunt (Zp) compartment. Zs was consistent with a large resistance and inertance, and Zp with a mainly elastic element having an elastance close to that of the tube walls. We conclude that Zrs data during EFL mainly reflect the properties of the FLE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Expiratory flow limitation during mechanical ventilation detected by the forced oscillation method.

We have previously observed large phasic variations of respiratory mechanical impedance in chronic obstructive pulmonary disease (COPD) patients mechanically-ventilated for acute respiratory failure, and postulated that they were due to expiratory flow limitation (EFL). The aim of this study was to test that assumption experimentally and to assess the value of impedance for automatic and noninv...

متن کامل

Estimation of lower airway resistance in expiratory flow limitation during mechanical ventilation

Determining the level of expiratory flow limitation (EFL) in critical mechanically ventilated patients is of clinical relevance for choosing appropriate respiratory treatment and/or pharmacological therapy. In many respiratory diseases, EFL arises from pathological changes in the mechanical properties of the bronchial tree. These properties cannot be evaluated using common lumped-parameter mode...

متن کامل

Ventilation patterns influence airway secretion movement.

BACKGROUND Retention of airway secretions is a common and serious problem in ventilated patients. Treating or avoiding secretion retention with mucus thinning, patient-positioning, airway suctioning, or chest or airway vibration or percussion may provide short-term benefit. METHODS In a series of laboratory experiments with a test-lung system we examined the role of ventilator settings and lu...

متن کامل

Heliox reduces respiratory system resistance in respiratory syncytial virus induced respiratory failure

INTRODUCTION Respiratory syncytial virus (RSV) lower respiratory tract disease is characterised by narrowing of the airways resulting in increased airway resistance, air-trapping and respiratory acidosis. These problems might be overcome using helium-oxygen gas mixture. However, the effect of mechanical ventilation with heliox in these patients is unclear. The objective of this prospective cros...

متن کامل

Respiratory mechanics studied by forced oscillations during artificial ventilation.

Potential advantages of the forced oscillation technique over other methods for monitoring total respiratory mechanics during artificial ventilation are that it does not require patient relaxation, and that additional information may be derived from the frequency dependence of the real (Re) and imaginary (Im) parts of respiratory impedance. We wanted to assess feasibility and usefulness of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 81 6  شماره 

صفحات  -

تاریخ انتشار 1996