Efficient schemes for robust IMRT treatment planning.
نویسندگان
چکیده
We use robust optimization techniques to formulate an IMRT treatment planning problem in which the dose matrices are uncertain, due to both dose calculation errors and interfraction positional uncertainty of tumour and organs. When the uncertainty is taken into account, the original linear programming formulation becomes a second-order cone program. We describe a novel and efficient approach for solving this problem, and present results to compare the performance of our scheme with more conventional formulations that assume perfect knowledge of the dose matrix.
منابع مشابه
Cerebral cortex dose sparing for glioblastoma patients: IMRT versus robust treatment planning
BACKGROUND To date, patients with glioblastoma still have a bad median overall survival rate despite radiation dose-escalation and combined modality treatment. Neurocognitive decline is a crucial adverse event which may be linked to high doses to the cortex. In a planning study, we investigated the impact of dose constraints to the cerebral cortex and its relation to the organs at risk for glio...
متن کاملA single-field integrated boost treatment planning technique for spot scanning proton therapy
PURPOSE Intensity modulated proton therapy (IMPT) plans are normally generated utilizing multiple field optimization (MFO) techniques. Similar to photon based IMRT, MFO allows for the utilization of a simultaneous integrated boost in which multiple target volumes are treated to discrete doses simultaneously, potentially improving plan quality and streamlining quality assurance and treatment del...
متن کاملEvaluation of the effects of dental filling material artifacts on IMRT treatment planning in patient with nasopharyngeal cancer
Background: Presence of artifacts, caused by dental filling high-Z materials (DFM), on intensity-modulated radiation therapy (IMRT) treatment plan CT images may lead to uncertainty in head and neck calculated dose distributions. Hence, the purpose of this study was to investigate the effects of DFM on the IMRT calculated dose distribution and consequent radiobiological derived outcomes for naso...
متن کاملStep-and-Shoot versus Compensator-based IMRT: Calculation and Comparison of Integral Dose in Non-tumoral and Target Organs in Prostate Cancer
Introduction Intensity-Modulated Radiotherapy (IMRT) is becoming an increasingly routine treatment method. IMRT can be delivered by use of conventional Multileaf Collimators (MLCs) and/or physical compensators. One of the most important factors in selecting an appropriate IMRT technique is integral dose. Integral dose is equal to the mean energy deposited in the total irradiated volume of the p...
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 51 21 شماره
صفحات -
تاریخ انتشار 2006