Ultraviolet radiometry with synchrotron radiation and cryogenic radiometry.
نویسندگان
چکیده
The combination of a cryogenic radiometer and synchrotron radiation enables detector scale realization in spectral regions that are otherwise difficult to access. Cryogenic radiometry is the most accurate primary detector-based standard available to date, and synchrotron radiation gives a unique broadband and continuous spectrum that extends from x ray to far IR. We describe a new cryogenic radiometer-based UV radiometry facility at the Synchrotron Ultraviolet Radiation Facility II at the National Institute of Standards and Technology. The facility is designed to perform a variety of detector and optical materials characterizations. The facility combines a high-throughput, normal incidence monochromator with an absolute cryogenic radiometer optimized for UV measurements to provide absolute radiometric measurements in the spectral range from 125 nm to approximately 320 nm. We discuss results on photodetector characterizations, including absolute spectroradiometric calibration, spatial responsivity mapping, spectroreflectance, and internal quantum efficiency. In addition, such characterizations are used to study UV radiation damage in photodetectors that can shed light on the mechanism of the damage process. Examples are also given for UV optical materials characterization.
منابع مشابه
A SURF beamline for synchrotron source-based absolute radiometry
A new source-based radiometry beamline was recently constructed at the Synchrotron Ultraviolet Radiation Facility (SURF III). The goal of this beamline is to establish a national source standard with a wide spectral range from the far ultraviolet to the infrared by using the calculability of SURF III. The new beamline is a straight-through white-light beamline with few, if any, optical componen...
متن کاملتشخیص میکوباکتریوم توبرکولوزیس به روش PCR در نمونه های خلط که با روش های معمول (گستره مستقیم، کشت و Bactec) منفی می شوند
In the present research work, a specific 285 bp DNA fragment was used for detection of Mycobacterium Tuberculosis complex. 100 samples were chosen randomly from sputum specimens that were negative with conventional methods (direct smear, culture, and radiometry), and examined by PCR 7 cases of them were positive. Also, 20 sputum specimens were obtained from suspected patients to tuberculosis, a...
متن کاملTOPICAL REVIEW Quantum radiometry
Conventionally defined, radiometry is the field that studies the measurement of electromagnetic radiation in terms of its power, spectral characteristics, and other parameters. The term applies to electromagnetic radiation characterization in a wavelength range from nanometers to tens of microns and at all optical power levels. Because radiometry is defined so broadly, a wide variety of measure...
متن کاملFricke dosimetry for synchrotron stereotactic radiotherapy
In synchrotron stereotactic radiotherapy (SSR) the tumor is loaded with a high Z element, and exposed to monochromatic x-rays from a synchrotron source, in stereotactic conditions. The SSR treatment efficiency is related to the heavy element concentration achievable in the tumor, to the radiation energy, and the irradiation geometry [1,2]. The experimental dose verification of SSR in three dime...
متن کاملThe Use of Cryogenic HEMT Amplifiers in Wide Band Radiometers
Advances in device fabrication, modelling and design techniques have made wide band, low noise cryogenic amplifiers available at frequencies up to 106 GHz. Microwave radiometry applications as used in radio astronomy capitalize on the low noise and large bandwidths of these amplifiers. Radiometers must be carefully designed so as to preclude sensitivity degradations caused by small, low frequen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 38 1 شماره
صفحات -
تاریخ انتشار 1999