Thermal model of oil power transformers with a tap changer
نویسندگان
چکیده
The paper presents a new method for on-line temperature calculation taking into account change in the tap changer position. The method introduces accurate calculation of the losses, depending on the current, average temperature of the winding, and tap changer position (it affects both Joules (DC) losses and stray losses). The thermal model itself is the common three-body model (for a transformer with two windings per phase), with temperature dependent thermal conductances. Elements of the model describing steady-state characteristics are determined based on detailed construction and calculation of distribution of losses in the windings using the finite-elements method (FEM) and calculation of distribution of temperatures using the detailed thermal-hydraulic network model (THNM). Detailed calculation of the losses and temperatures enables the determination of the hot-spot factor (H = Q S) ; factor Q describes the nonuniform losses and factor S describes nonuniform cooling. The paper shows how these factors depend on tap changer position and the load.
منابع مشابه
Extending Operational Zone of Rotary Power Flow Controller by Controlling Tap-changers of Transformers
This paper proposes a method for extending the ability of rotary power flow controller (RPFC) using tap-changer of the RPFC’s transformers. A detailed model of the device is presented to analyze the effects of the tap changer operation on the performance of the RPFC. To evaluate the results, the RPFC model is simulated using PSCAD/EMTDC software. Dynamic operation of the RPFC on a 400 kV transm...
متن کاملEffect of Solid-State on Load Distribution Transformer Tap-Changer on Power Quality Enhancement
Recently electronic tap-changer has received more attention due to its quick response, better performance and simpler maintenance compared to the mechanical tap-changer. This paper presents the capability of the distribution transformer equipped with an electronic tap-changer for improving power quality. At this end, the analytical computation for determining the compensating limit of electroni...
متن کاملA Sensitive ANN Based Differential Relay for Transformer Protection with Security against CT Saturation and Tap Changer Operation
This paper presents an artificial neural network (ANN) based scheme for fault identification in power transformer protection. The proposed scheme is featured by the application of ANN to identifying system patterns, the unique choice of harmonics of positive sequence differential currents as ANN inputs, the effective handling of current transformer (CT) saturation with an ANN based approach, an...
متن کاملArtificial Neural Network for Parallel Transformers Tap-changer Control for Closed Primary Bus Connection
Voltage control is an essential part of the electric energy transmission and distribution system to maintain proper voltage limit at the consumer’s terminal. Besides the generating units that provide the basic voltage control, there are many additional voltage-controlling agents e.g., shunt capacitors, shunt reactors, static VAr compensators, regulating transformers mentioned in [1], [2]. The m...
متن کاملAnalysis of Power Transformer using fuzzy expert and neural network system
Power transformers being the major apparatus in a power system, thus the assessment of transformer operating condition and lifespan have obtained crucial significance in latest years. Dissolved gas analysis (DGA) is a sensitive and reliable technique for the detection of incipient fault condition within oil-immersed transformers, which provides the basis of diagnostic evaluation of equipment he...
متن کامل