Rapid Detection Technology for Pesticides Residues Based on Microelectrodes Impedance Immunosensor

نویسندگان

  • Wen Ping Zhao
  • Guo Zhao
  • Dong Fei Chen
  • Zhi Huai Mao
  • Xiang You Wang
چکیده

Compared with conventional methods, electrochemical immunosensors have many advantages, such as low cost, high sensitivity, and rapid detection, and has certain prospects for realizing real-time-monitoring. In this paper, a design of portable pesticide residues detection instrument was presented based on an electrochemical impedance immunosensor. Firstly, we studied on an impedance immunosensor based on interdigitated array microelectrode (IDAM) coupled with magnetic nanobeads-antibody conjugates (MNAC) for the pesticide detection. Magnetic nanobeads (diameter 150 nm) coated with anti-carbofuran antibodies were used for further amplification of the binding reaction between antibody and hapten (carbofuran). Secondly, in order to develop a portable pesticide residue apparatus, we designed the impedance detection electric circuit. Main work included designing and constructing of the system circuit, designing and debugging of the system software and so on. Thirdly, the apparatus was used for the standard pesticides solutions testing combined with immunosensor to test the reliability and stability. The pesticide added standard recovery was more than 70 % and the impedance test error was less than 5 %. The results showed that the proposed instrument had a good consistence compared with the traditional analytical methods. Thus, it would be a promising rapid detection instrument for pesticide residues in agricultural products. Copyright © 2014 IFSA Publishing, S. L.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Portable Pesticide Residues Detection Instrument Based on Impedance Immunosensor

In this paper, a design of portable pesticide residues detection instrument was presented based on an impedance immunosensor. The immunosensor exploited the novel multilayer films based on Au nanoparticles (AuNPs) and polyaniline/carboxylated multiwall carbon nanotubes-chitosan nanocomposite (PANI/MWCNTs/CS). The detection principle of the instrument was based on the electrochemical characteris...

متن کامل

Electrochemical Impedance Immunosensor Based on Self-Assembled Monolayers for Rapid Detection of Escherichia coli O157:H7 with Signal Amplification Using Lectin

Escherichia coli O157:H7 is a predominant foodborne pathogen with severe pathogenicity, leading to increasing attention given to rapid and sensitive detection. Herein, we propose an impedance biosensor using new kinds of screen-printed interdigitated microelectrodes (SPIMs) and wheat germ agglutinin (WGA) for signal amplification to detect E. coli O157:H7 with high sensitivity and time-efficien...

متن کامل

A Label-Free Electrochemical Immunosensor for Carbofuran Detection Based on a Sol-Gel Entrapped Antibody

In this study, an anti-carbofuran monoclonal antibody (Ab) was immobilized on the surface of a glassy carbon electrode (GCE) using silica sol-gel (SiSG) technology. Thus, a sensitive, label-free electrochemical immunosensor for the direct determination of carbofuran was developed. The electrochemical performance of immunoreaction of antigen with the anti-carbofuran monoclonal antibody was inves...

متن کامل

Electrochemical Immunosensor for Pesticide Residues Detection in Food Analysis

Electrochemical immunosensors have emerged as a highly sensitive and rapid technique for chemical contaminants detection in environmental monitoring, food safety and quality control. This review concentrates on recent advances made in detection and quantification of chemical contaminants such as pesticides and antibiotics residues with electrochemical immunosensors. In this paper, the preparati...

متن کامل

Impedance Immunsensor Based on Interdigitated Array Microelectrode and its Experiment Parameter Optimization

This article accounts for a novel impedance immunosensor based on the specificity reaction of the antigen-antibody and the sensitivity of the interdigitated array microelectrode (IDAM) for the determination of chlorpyrifos residues. The basic knowledge of immunoassay was in relation to its IDAM electrode surface modification, antibody immobilization, bovine serum albumin (BSA) blocking and samp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014