Hemodynamics of Portal Hypertension with 4D Radial Phase Contrast Imaging: Feasibility at 3.0T

نویسندگان

  • R. W. Verma
  • K. Johnson
  • B. Landgraf
  • A. Frydrychowicz
  • C. J. Francois
  • O. Wieben
  • S. B. Reeder
چکیده

Introduction: Portal hypertension (PHTN) is a complication of cirrhosis associated with significant morbidity, including varices, variceal rupture, ascites, portal venous thrombosis, and encephalopathy. Current non-invasive evaluation of PHTN is confined to angiographic assessments with MRA and CTA and limited hemodynamic assessment with ultrasound. Recent work has described the ease of demonstrating 4D flow characteristics in the portal venous system to obtain anatomical and quantitative information [1]. The purpose of this study is to demonstrate the feasibility of 3D radial phase contrast imaging for high-resolution comprehensive evaluation of the hemodynamics of PHTN using a 32-channel phased array coil at 3.0T. Comprehensive PC imaging in the liver is challenging due to the markedly different velocities in the hepatic artery and tributaries of the portal vein, which can change dramatically with disease. To image a wide range of velocities without velocity aliasing or increased noise, a highly efficient 5point velocity encoding strategy was employed [2]. Methods: After obtaining informed consent according to this IRB-approved study, MRI studies were performed in two normal volunteers (2 males, both age 23) and in five patients (M=2, ages 58-66; F=2, ages 23-57) with known cirrhosis and PHTN was performed. All imaging was performed on a 3.0T clinical scanner (MR750 v20.0, GE Healthcare, Waukesha, WI) using a 32-channel phased array body coil (Neocoil, Pewaukee, WI). Images were acquired using a 3D radially undersampled PC sequence (PC-VIPR) as previously described [3], using respiratory gating [4] and retrospective cardiac gating. Specific image parameters included: FOV=32cm, BW=125 kHz, with 24,000 total projections, for true isotropic spatial resolution of 1.3 x 1.3 x 1.3mm, temporal resolution of 74ms, VENC=60cm/s, and total scan time on the order of 10 minutes. 20 interpolated time frames were reconstructed with an automated offline reconstruction algorithm. Angiographic images derived from the PC images were segmented using Mimics (Materialise, Ann Arbor, MI), and analyzed using commercially available analysis and visualization software (Ensight 9.0 CEI, Apex, NC). Results: Excellent image quality was achieved in all volunteers and patients. Flow was demonstrated in both the hepatic arteries and portal veins. Examples are shown in figures 1-4 using different segmentation and velocity visualization approaches. Figure 1 demonstrates a pattern of right-handed helical flow in the portal vein of a volunteer. Particle tracings used blue seed points in the splenic vein and red points in the superior mesenteric vein (SMV) to demonstrate the helicity of this laminar flow. Figure 2 shows images from a 58 yo male cirrhotic with cryptogenic cirrhosis demonstrating normal flow direction in the portal vein and splenic vein (hepatopetal flow), but reversed flow in several small tributaries of the portal vein, including the coronary vein and inferior mesenteric vein. Figure 3 show images from a 23 yo woman with a history of biliary atresia, repaired a neonate with a hepaticojejunostomy (Kasai procedure), now presenting for liver transplant from end-stage cirrhosis from chronic biliary stasis. Complete reversal of flow in the portal vein and splenic vein (hepatofugal flow) was seen, along with reversed venous through massive spleno-renal varices. Figure 4 shows a 66 yo male with end-stage cirrhosis, and two recanalized paraumbilical varices draining the left portal vein in a parallel manner, which had hepatopetal flow. Stream-line visualization shows an unusual configuration of these parallel paraumbilical veins that had a narrow connection superiorly. The hepatic artery is also well visualized (red).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diurnal Variation of Portal Hemodynamics with 4D flow MRI

Target audience: Researchers and clinicians interested in 4D flow for non-invasive assessment of mesenteric circulation and portal hypertension. Introduction: Portal hypertension is an end-stage complication of cirrhosis that leads to dramatic and complex alterations in the hemodynamics of the hepatic and the mesenteric circulation. Currently, there are few valid quantitative biomarkers to asse...

متن کامل

Quantification of blood flow in the portal circulation before and after an intervention

Background Hemodynamic and morphological assessment of portal hypertension (PHTN) is challenging due to the dual blood supply to the liver and complex and variable anatomy. Additionally, in the presence of liver disease such as cirrhosis, the increased resistance to flow leads to changes in hepatic and splanchnic blood flow, which if measured, could have diagnostic value. Accurate noninvasive a...

متن کامل

Visualization and Quantification of 3D Flow Characteristics in the Portal Venous System

Introduction: Chronic liver disease is an important cause of morbidity and mortality. Almost 20% of patients have cirrhosis at presentation [1]. Previous studies have shown that alteration of hepatic perfusion parameters measured with CT or ultrasound in patients with liver cirrhosis correlate with the severity of chronic liver disease and the therapeutic outcome [2,3]. Recent studies assess li...

متن کامل

Feasibility of 4D flow MR imaging of the brain with either Cartesian y-z radial sampling or k-t SENSE: comparison with 4D Flow MR imaging using SENSE.

PURPOSE A drawback of time-resolved 3-dimensional phase contrast magnetic resonance (4D Flow MR) imaging is its lengthy scan time for clinical application in the brain. We assessed the feasibility for flow measurement and visualization of 4D Flow MR imaging using Cartesian y-z radial sampling and that using k-t sensitivity encoding (k-t SENSE) by comparison with the standard scan using SENSE. ...

متن کامل

FDG-avid portal vein tumor thrombosis from hepatocellular carcinoma in contrast-enhanced FDG PET/CT

Objective(s): In this study, we aimed to describe the characteristics of portal vein tumor thrombosis (PVTT), complicating hepatocellular carcinoma (HCC) in contrast-enhanced FDG PET/CT scan. Methods: In this retrospective study, 9 HCC patients with FDG-avid PVTT were diagnosed by contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT), which is a comb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009