Determination of chromium(III) and total chromium in water by derivative atomic absorption spectrometry using flow injection on-line preconcentration with a double microcolumn.
نویسندگان
چکیده
A rapid and sensitive method has been proposed for the sequential determination of chromium(III) and total chromium in water samples by flame atomic absorption spectrometry combined with a flow injection on-line preconcentration on a double-microcolumn. The chromium(III) and total chromium in samples were retained on a double-microcolumn with a cation exchange resin, respectively, and eluted directly into a nebulizer by 3 mol L(-1) HNO3. The characteristic concentration (gives a derivative absorbance of 0.0044) and the detection limit (3sigma) for chromium were 0.512 microg L(-1) and 0.647 microg L(-1) for a preconcentration time of 1 min, respectively. This is an improvement of 20 and 14-times than those of conventional FI-FAAS. The proposed method allows the determination of chromium in the range of 0-90 microg L(-1) with a relative standard deviation of 3.63% at the 10 microg L(-1) level. The method has been applied for the analysis of chromium in reference water of National Research Center for Certified Reference Materials (GBW08607) and other water samples with satisfactory results.
منابع مشابه
Preconcentration and Speciation of Chromium Using Dispersive Liquid-Liquid Microextraction; Application to Milk and Different Water Samples
A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) was developed for determination and speciation of trace amounts of chromium (Cr) by flame atomic absorption spectrometry (FAAS). In the proposed approach, chloroform and methanol were used as extraction and dispersive solvents. A new Schiff's base ligand, bis(2-methoxy benzaldehyde) ethylene d...
متن کاملDetermination of trace amounts of chromium ions in water and food samples using ligand-less solid phase extraction-based modified nano-boehmite(AlOOH)
Chromium is one of the hazardous pollutants in industrial effluents. In this study, a new nano-boehmite modified with sodium dodecyl sulphate is developed for preconcentration trace amounts of chromium ions as a prior step to its determination by flame atomic absorption spectrometry. We investigated the effect of various parameters on the recovery of the analyte ions, including pH of sample solut...
متن کاملDetermination of chromium(VI) and lead in water samples by on-line sorption preconcentration coupled with flame atomic absorption spectrometry using a PCTFE-beads packed column.
A new time-based flow injection on-line solid phase extraction method for chromium(VI) and lead determination using flame atomic absorption spectrometry was developed. The use of hydrophobic poly-chlorotrifluoroethylene (PCTFE)-beads as absorbent in on-line preconcentration system was evaluated. Effective formation of ammonium pyrrolidine dithiocarbamate complexes and subsequently retention in ...
متن کاملFlow-Injection Flame Atomic Absorption Determination of Hexavalent Chromium with On-Line Preconcentration on an Anion Imprinted Polymer
A flow injection preconcentration system for the flame atomic absorption spectrometric determination of hexavalent chromium has been developed. The method employs on-line preconcentration of Cr(VI) on a minicolumn packed with Cr(VI)-imprinted poly(4-vinyl pyridine-co-2-hydroxyethyl methacrylate) placed into a flow injection system. Hexavalent chromium was eluted with a small volume of diluted h...
متن کاملContinuous approach for ultrasound-assisted acid extraction-minicolumn preconcentration of chromium and cobalt from seafood samples prior to flame atomic absorption spectrometry.
A rapid and sensitive method has been proposed for the determination of chromium and cobalt in seafood samples by flame atomic absorption spectrometry combined with a dynamic ultrasound-assisted acid extraction and an on-line minicolumn preconcentration. The use of diluted nitric acid as extractant in a continuous mode at a flow rate of 3.5 mL min(-1) and room temperature was sufficient for qua...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 19 4 شماره
صفحات -
تاریخ انتشار 2003