The need to protect the thyroid gland during image intensifier use in orthopaedic procedures.
نویسندگان
چکیده
The image intensifier has become an essential part of the orthopaedic surgeon's armamentarium. Its increasing use, however, may expose medical staff and theatre personnel to high doses of radiation. The aim of this study was to assess the compliance of surgeons and staff with radiation protection protocols, especially the use of the thyroid shield and to calculate the radiation exposure dose during routine orthopaedic procedures. We carried out this prospective study of 44 consecutive cases at the Rochdale Infirmary. The total dose of radiation and the total number of images taken were found to be more during hip surgery such as dynamic hip screw fixation for intertrochanteric fracture (1,715.5 mGy.cm2) and the intramedullary nailing (4,357.5 mGy.cm2). However the total percentage of the theatre personnel wearing thyroid shield was as low as 4% (14 people out of total 345 people present in theatre in 44 procedures) in spite of its availability. The consistent neglect in the use of the thyroid shield by surgeons and nursing staff present in theatre during fluoroscopically assisted procedures is a matter for concern. The data presented in this study will emphasise the need to wear a thyroid collar during orthopaedic procedures and the need for better guidelines to protect theatre personnel as well as patients from radiation exposure hazards.
منابع مشابه
Thyroid dose and dose reduction method from CT scan of head and neck
Introduction: Computed tomography (CT) consists of 11% of all imaging methods, but accounts for approximately 67% of radiation exposure due to diagnostic cases. More than one-third of all CT scans are done in the head and neck area. The thyroid gland is irradiated during CT head and neck. According to studies, this gland has the highest levels of radiation-induced cancer, and i...
متن کاملUltrasonographic Volumetry of the Canine Thyroid Gland: A Comparison of 2D, 3D Ultrasonography and Real Gland Volume
Objective: to compare the estimated thyroid volume, as determined by two-dimensional (2D) and three-dimensional (3D) ultrasonography, with real volume. Design: Descriptive Study Animals: A total of 7 mixed breed dogs Procedures: On 2D ultrasound, the thyroid volume is estimated by the ellipsoid equation and on 3D ultrasound; it is estimated by outlining the boundaries of the thyroid lobe in ...
متن کاملEntrance surface dose measurement on the thyroid gland in orthopantomography: The need for optimization
Background: The anatomic position and proven radiosensitivity of the thyroid make it an organ of concern in dental X-ray examinations. A National Radiation Protection Department (NRPD)-sponsored pilot study carried out in the Dental Radiology Department of RUMS., to assess if the radiation dose in panoramic radiographies could be reduced without significant impairment of the subjective image qu...
متن کاملDose Reduction to the Thyroid Gland in Pediatric Chest Radiography
Background It is remain a main concern that pediatric chest radiographies contribute to the significant radiation exposure to the thyroid gland as a more susceptible organ to radiation induced cancer. The aim of this study was to evaluate the entrance surface dose (ESD) of pediatric chest radiography compared to the diagnostic reference levels (DRL) and evaluation the efficacy of the lead (Pb)...
متن کاملAn Estimate of Radiation Dose to the Lens of the Eyes, Parotid Gland, and Thyroid Gland in Dental Panoramic Radiography
Introduction: Dental panoramic radiography (DPR) is one of the most frequent diagnostic X-ray procedures, the application of which is currently on a growing trend. During DPR, several radiosensitive tissues, such as the lens of the eyes, parotid gland, and thyroid gland, contribute to the radiation field, and it is necessary to monitor their received dose. The aim of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 70 5 شماره
صفحات -
تاریخ انتشار 2004