Quantification of and Correction for Left Ventricular Systolic Long-Axis Shortening

نویسندگان

  • Walter J. Rogers
  • Maurice B. Buchalter
  • Frank E. Rademakers
  • Myron L. Weisfeldt
چکیده

a fixed plane and fail to compensate for through-plane motion. The shortening of the left ventricle along its long axis during systole results in planar images of two different levels of the ventricle, leading to error in any derived functional measurements. LV systolic long-axis motion was measured in 19 normal volunteers using MRI. Methods and Results. With a selective radio frequency (RF) tissue-tagging technique, three short-axis planes were labeled at end diastole and standard spin-echo images were acquired at end systole in the twoand four-chamber orientations. Persistence of the tags through systole allowed visualization of the intersecting short-axis tags in the long-axis images and allowed precise quantification of long-axis motion of the septum, lateral, anterior, and inferior walls at the base, mid, and apical LV levels. The total change in position along the long axis between end diastole and end systole was greatest at the base, which moved toward the apex 12.8+±3.8 mm. The mid left ventricle moved 6.9±2.6 mm, and the apex was nearly stationary, moving only 1.6±2.2 mm (p<O.OO1). Having quantified the normal range of long-axis shortening, we developed a technique that isolates a slice of tissue between selective RF saturation planes at end diastole. Combining this with a wide end-systolic image slice, end-systolic images were acquired without contamination of signal from adjacent tissue moving into the imaging plane. This technique was validated in a moving phantom and in normal volunteers. Conclusions. Significant LV systolic long-axis shortening exists, and this effect is seen the most at the base and the least at the apex. At a given ventricular level, shortening varied significantly according to location. A method using selective saturation pulses and gated spin-echo MRI automatically corrects for this motion and thus eliminates misregistration artifact from regional function analysis. (Circulation 1991;84:721-731)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of and correction for left ventricular systolic long-axis shortening by magnetic resonance tissue tagging and slice isolation.

BACKGROUND Measurement of regional left ventricular (LV) function is predicted on the ability to compare equivalent LV segments at different time points during the cardiac cycle. Standard techniques of short-axis acquisition in two-dimensional echocardiography, cine computed tomography, and standard magnetic resonance imaging (MRI) acquire images from a fixed plane and fail to compensate for th...

متن کامل

Echocardiographic assessment of myocardial infarction: comparison of a rat model in two strains

The purpose of this study was to induce myocardial infarction (MI) and compare the echocardiographic parameters and mortality ratio of Lewis inbred and Wistar outbred strain before and after the procedure to help choose the best one for MI studies. In this study MI was induced in 46 Lewis and 34 Wistar by occlusion of left anterior descending artery (LAD). Doppler, two-dimensional (2-D) and 2-D...

متن کامل

Maternal left ventricular transverse and long-axis systolic function during pregnancy.

OBJECTIVES Circumferential fiber shortening has been the dominant basis for conventional analysis by echocardiography of left ventricular systolic function during pregnancy. Results in the literature have been conflicting due mainly to the fact that geometric assumptions for the calculation of these indices are made that may not be valid due to changes in left ventricular shape during pregnancy...

متن کامل

Functional importance of the long axis dynamics of the human left ventricle.

The role of longitudinally and circumferentially oriented fibres in left ventricular wall motion was examined by digitising echocardiograms of the mitral ring (whose motion reflects long axis change) and of the standard minor axis in 36 healthy individuals, 36 patients with coronary artery disease, 16 with left ventricular hypertrophy, 44 with mitral valve disease (24 of whom had undergone mitr...

متن کامل

A new method for quantification of left ventricular systolic function using a corrected ejection fraction.

AIMS Left ventricular ejection fraction (EF) is a suboptimal measure of ventricular function. Recent mathematical modelling of left ventricular contraction has shown that the EF is determined by both myocardial shortening (strain) and by end-diastolic wall thickness. Increasing end-diastolic wall thickness resulted in augmented radial wall thickening. This may result in a significant 'overestim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005