Investigation of Lanthanum Scintillators for 3-D PET
نویسندگان
چکیده
The main thrust for this work is the investigation and design of a positron emission tomography (PET) scanner based on new Lanthanum Halide scintillators. In three–dimensional (3-D) PET the major limitations are scanner dead-time and ability to reject randoms and scatter. Therefore, to reach the full potential of 3-D PET requires a scintillator with good timing resolution and good energy resolution. The new Lanthanum Halide scintillators have very fast decay and very high light output which leads to timing resolution and energy resolution that are both superlative. For application to PET, the authors have constructed pixels with dimensions 4 4 30 mm and have measured energy resolution of 4.6% (fwhm) at 662 keV and a timing resolution (fwhm) of 350 ps, in coincidence with a plastic scintillator. Using a detector based on LaBr3, a 3-D PET scanner with 90 cm diameter and 25 cm axial extent is predicted to achieve a sensitivity of 1400 kc/s Ci cc and a peak NEC count-rate of 120 kc/s using the NEMA NU2-2001 standard. Further, the excellent timing resolution opens the possibility of measuring time-of-flight with sufficient accuracy to reduce the noise propagation during image reconstruction, thus leading to a significant gain in signal-to-noise. Assuming a system timing resolution of 500 ps, one can expect the effective NEC to increase by a factor of 3 for a thin patient (20 cm diameter) and a factor 6 for a very heavy patient (40 cm diameter). Thus, even with lower stoping power than other PET scanners, the combination of excellent energy resolution and timing resolution of LaBr3 can potentially lead to a very significant improvement in PET performance.
منابع مشابه
Image quality assessment of LaBr3-based whole-body 3D PET scanners: a Monte Carlo evaluation.
The main thrust for this work is the investigation and design of a whole-body PET scanner based on new lanthanum bromide scintillators. We use Monte Carlo simulations to generate data for a 3D PET scanner based on LaBr3 detectors, and to assess the count-rate capability and the reconstructed image quality of phantoms with hot and cold spheres using contrast and noise parameters. Previously we h...
متن کاملSpectroscopy with next generation scintillator arrays
Historically, gamma-ray spectroscopy has transitioned from using scintillator detectors with high efficiency but relatively low energy resolution to germanium detectors with high intrinsic energy resolution but much lower intrinsic efficiency. Next-generation scintillator materials such as lanthanum bromide, cerium bromide have become available over the last decade offering significantly improv...
متن کاملA feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators
We present a study of the application of the Jagiellonian positron emission tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PET is the first positron emission tomography scanner based on organic scintillators in contrast to all current PET scanners based on inorganic crystals. Monte Carlo simulations show that the J-PET as an axially symmetr...
متن کاملNonproportional response of LaBr3:Ce and LaCl3:Ce scintillators to synchrotron x-ray irradiation.
The nonproportional scintillation response of LaBr(3) doped with 5% Ce(3+) and of LaCl(3) doped with 10% Ce(3+) was measured using highly monochromatic synchrotron irradiation. To estimate the photon response, pulse height spectra at many finely spaced energy values between 9 and 100 keV were measured. The experiment was carried out at the X-1 beamline at the Hamburger Synhrotronstrahlungslabor...