Voltage Sag Effect on Three Phase Five Leg Transformers
نویسندگان
چکیده
The behavior of three phase five leg transformer under voltage sag is studied in this paper. This paper proposes a simple, practical model of a three phase-five leg, saturated transformer with accurate performance. Transformer saturation is produced when the voltage sag is recovered and it causes inrush current in transformer. Effects of voltage sag depth, duration and initial point on wave have been analyzed in this paper. Initial point on wave can produce maximum inrush current in five leg transformers while comparing with three leg transformers. The magnetic circuit symmetry of five leg transformer produces the more symmetrical shape of inrush current curves versus initial point on wave and sag duration than three leg transformer. The simulations show that current peak has a periodical dependence on sag duration and linear dependence on sag depth. Inrush current that is produced in three phase five leg transformer is higher than three phase three leg transformer. Keywords—Inrush current, three phase five leg transformer, saturation, voltage sag.
منابع مشابه
Effect of transformer on stochastic estimation of voltage sag due to faults in the power system: a PSCAD/EMTDC simulation
Voltage sags in the electric power system are mostly due to faults in the power system. Voltage sag is characterized by its magnitude (the retained voltage), phase-angle jump, unbalance in the sag in the three phases, and duration. Type of transformers in the electrical system is the important parameter influencing the characteristic of sag at the node where sensitive loads are connected. For s...
متن کاملClassification of Voltage Sag Causes using Probabilistic Neural Network and Hilbert – Huang Transform
Any power quality disturbance waveform can be seen as superimposition of various oscillating modes. It becomes necessary to separate different components of single frequency or narrow band of frequencies from a non stationary signal to identify the causes which contribute to power quality disturbances. In this paper a method is proposed to detect and classify voltage sag causes based on Empiric...
متن کاملWavelet Transform for Classification of Voltage Sag Causes using Probabilistic Neural Network
This paper presents an algorithm to detect and classify voltage sag causes based on Wavelet Transform (WT) and Probabilistic Neural Network (PNN). A technique is required which is capable of extracting both time-frequency information to identify the causes which contribute to power quality disturbances. Wavelet transform based on multiresolution analysis is used to extract the features from the...
متن کاملHarmonic Modeling of Inrush Current in Core Type Power Transformers Using Hartley Transform
This paper presents a new method for evaluation and simulation of inrush current in various transformers using operational matrices and Hartley transform. Unlike most of the previous works, time and frequency domain calculations are conducted simultaneously. Mathematical equations are first represented to compute the inrush current based on reiteration and then Hartley transform is used to stud...
متن کاملPower Quality Enhancement Using VSC Based DSTATCOM
In this paper, a new three-phase four-wire distribution static compensator (DSTATCOM) based on a T-connected transformer and a three-leg voltage source converter (VSC) is proposed for power quality improvement. The T-connected transformer connection mitigates the neutral current and the three-leg VSC compensates harmonic current, reactive power, and balances the load. Two single-phase transform...
متن کامل