Cell-free protein expression in a microchannel array with passive pumping.
نویسندگان
چکیده
We report in vitro (cell-free) protein expression in a microfluidic device using passive pumping. The polystyrene device contains 192 microchannels, each of which is connected to two wells positioned in a 384-well microplate format. A larger droplet of an expression solution was placed at one well of each channel while a smaller droplet of a nutrient solution was at the other well. Protein expression took place in the larger droplet and we found the expression yield in the expression solution is enhanced due to the replenishment of the nutrient solution supplied by passive pumping via the channel. The pumping pressure was generated from the difference in the surface tension between two different sized droplets at the two wells. We demonstrated expression of luciferase in the device and the expression yield was measured using luminescence assay. Different experimental conditions were investigated to achieve maximum protein yield with the least amount of reagents. Protein expression yields were found to be dependent on the amount of the nutrient solution pumped, independent of the amount of the expression solution within the experimental conditions studied. A higher feeding frequency or delivery rate of the nutrient solution resulted in higher protein expression yield. The work demonstrated the feasibility of using the microchannel array for protein expression with the following advantages: (1) simultaneous production of the same protein with different conditions to optimize the expression process; (2) simultaneous production of different proteins for high-throughput protein expression with high yield; (3) low reagent cost due to the fact that it consumes 125-800 times less than the amount used in a protein expression instrument commercially available.
منابع مشابه
A passive pumping method for microfluidic devices.
The surface energy present in a small drop of liquid is used to pump the liquid through a microchannel. The flow rate is determined by the volume of the drop present on the pumping port of the microchannel. A flow rate of 1.25 microL s(-1) is demonstrated using 0.5 microL drops of water. Two other fluid manipulations are demonstrated using the passive pumping method: pumping liquid to a higher ...
متن کاملThree-dimensional CFD modeling of fluid flow and heat transfer characteristics of Al2O3/water nanofluid in microchannel heat sink with Eulerian-Eulerian approach
In this paper, three-dimensional incompressible laminar fluid flow in a rectangular microchannel heat sink (MCHS) using Al2O3/water nanofluid as a cooling fluid is numerically studied. CFD prediction of fluid flow and forced convection heat transfer properties of nanofluid using single-phase and two-phase model (Eulerian-Eulerian approach) are compared. Hydraulic and thermal performance of microch...
متن کاملInduced pressure pumping in polymer microchannels via field-effect flow control.
Microfluidic field-effect flow control (FEFC) modifies the zeta potential of electroosmotic flow using a transverse electric field applied through the microchannel wall. Previously demonstrated in silicon-based and glass microsystems, FEFC is presented here as an elegant method for flow control in polymer-based microfluidics with a simple and low-cost fabrication process. In addition to direct ...
متن کاملPower-free sequential injection for microchip immunoassay toward point-of-care testing.
This paper presents a simple fluid handling technique for microchip immunoassay. Necessary solutions were sequentially injected into a microchannel by air-evacuated poly(dimethylsiloxane), and were passively regulated by capillary force at the inlet opening. For heterogeneous immunoassay, microchips are potentially useful for reduction of sample consumption and assay time. However, most of the ...
متن کاملTwo-fluid Electrokinetic Flow in a Circular Microchannel (RESEARCH NOTE)
The two-fluid flow is produced by the combined effects of electroosmotic force in a conducting liquid and pressure gradient force in a non-conducting liquid. The Poisson-Boltzmann and Navier-Stokes equations are solved analytically; and the effects of governing parameters are examined. Poiseuille number increases with increasing the parameters involved. In the absence of pressure gradient, the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Lab on a chip
دوره 9 1 شماره
صفحات -
تاریخ انتشار 2009