Study on the Best Water Cushion Depth of Stilling

نویسندگان

  • Qiulin Li
  • Lianxia Li
  • Huasheng Liao
  • Jingjing Wei
  • Shengyin Jiang
  • Faxing Zhang
چکیده

The water cushion depth of stilling basin with shallow-water cushion is a key factor that 13 affects the flow regime of hydraulic jump in the basin. However, the specific depth at which the 14 water cushion is considered as “shallow” has not be stated clearly for now, and only conceptual 15 description is provided. This paper attempts to specify the best water cushion depth based on the 16 flow regime of hydraulic jump and underflow speed; namely, in case of critical hydraulic jump in 17 the basin, the best water cushion depth is located where the minimum distance to the bottom plate 18 of the stilling basin is 1/5~1/4 of the water cushion depth. The theoretical analysis indicates, at 19 different inclinations of discharge chute (θ) and depth ratios of inlet (m), instead of monotonic 20 change, the Froude number (Fr) at inlet of the stilling basin with shallow-water cushion firstly 21 reduces and then increases as the flow velocity at discharge chute inlet (V) increases; the parameters 22 of inflection point (critical flow velocity and critical Fr) increase as the inclinations of discharge chute 23 (θ) and depth ratios of inlet (m) increase. Such regularity is the theoretical basis for selecting 24 representative study cases. The reliability of the large eddy simulation calculation results are 25 verified by a model test; in the paper, 30 cases including five different Froude numbers and six 26 shallow-water cushion depths are selected, for calculating the hydraulic factors such as flow profile, 27 flow regime and flow velocity in the stilling basin with shallow-water cushion; and the varying 28 pattern between the best depth of stilling basin with shallow-water cushion (depth-to-length ratio) 29 and the inflow Froude number is obtained which indicates that the best depth of stilling basin with 30 shallow-water cushion varies little as the change of the Froude number before reaching the critical 31 Froude number; however, the best depth-to-length ratio of stilling basin with shallow-water cushion 32 increases as the Froude number increases after the critical Froude number is reached. The study 33 results in this paper are of reference significance to design and calculation of the stilling basin with 34 shallow-water cushion. 35

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characteristics of S-jump on Roughened Bed Stilling Basin

Formation of hydraulic jump is necessary for dissipation of the excess kinetic energy downstream of spillways and gates. Hydraulic jump stilling basins of sudden expansion are one of the energy dissipater structures which are used where the available tail water depth is less than the required sequent depths. In the present study to further reduce the hydraulic jump sequent depths ratio, a rough...

متن کامل

The Effect of Six-Legged Concrete Elements on Hydraulic Jump Characteristics

In the present study, the six legged concrete (SLC) elements are placed at the bed of a flume downstream of a chute in different layouts, densities and number of longitudinal rows of SLC elements. Each test was run for different flow conditions (Froude numbers ranged 5.3 to 8.1). During each test, the water surface profile, the roller length and the jump length measured.  Applying the experimen...

متن کامل

New Stilling Basins Designs for Deep Rectangular Outlets

The experimental study reported here is intended to evolve new designs of stilling basins for deep and narrow openings used as outlets. Several appurtenances such as grid, Impact wall, stepped wall, weir wall, sloping end sill and wedge shaped blocks are used to study their influence on the hydraulic performance of the stilling basins with an aim to propose efficient stilling basin models. All ...

متن کامل

Experimental Investigation of the Characteristics of Hydraulic Jump in a Diverging Stilling Basin with an Adverse Slope Using Baffle Blocks

Stilling basins have been used as an energy dissipater downstream of hydraulic structures. Dimensions of the stilling basins depends on hydraulic jump characteristics. In this research diverging hydraulic jump with an adverse slope using baffle blocks and an end sill have been studied experimentally and effect of diverging angle of the walls, adverse bed slope and baffle blocks on the hydraulic...

متن کامل

Forced Hydraulic Jump by One and Two Continuous Sills in a Horizontal Stilling Basin.

Forced hydraulic jump in a horizontal stilling basin with one and two continuous sills at the downstream end of an ogee standard weir was investigated. Experiments were completed on sills of five different heights which were fixed at two different distances from the toe of the weir. The main characteristics of the jump such as the sequent depth ratio, relative roller length, and relative ener...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -