Scanning focused refractive-index microscopy
نویسندگان
چکیده
We present a novel scanning focused refractive-index microscopy (SFRIM) technique to obtain the refractive index (RI) profiles of objects. The method uses a focused laser as the light source, and combines the derivative total reflection method (DTRM), projection magnification, and scanning technique together. SFRIM is able to determine RIs with an accuracy of 0.002, and the central spatial resolution achieved is 1 µm, which is smaller than the size of the focal spot. The results of measurements carried out on cedar oil and a gradient-refractive-index (GRIN) lens agree well with theoretical expectations, verifying the accuracy of SFRIM. Furthermore, using SFRIM, to the best of our knowledge we have extracted for the first time the RI profile of a periodically modulated photosensitive gelatin sample. SFRIM is the first RI profile-resolved reflected light microscopy technique that can be applied to scattering and absorbing samples. SFRIM enables the possibility of performing RI profile measurements in a variety of applications, including optical waveguides, photosensitive materials and devices, photorefractive effect studies, and RI imaging in biomedical fields.
منابع مشابه
Control capability of electrolytic concentration on refractive index and dielectric constant of porous Silicon layers
Porous Silicon (PS) samples have been prepared by electrochemical anodization of p-type silicon wafer by varying HF concentrations in the electrolytic solution. The structural, surface morphological, optical and surface composition analysis of the prepared samples were done by X-ray diffraction (XRD), Scanning electron microscopy (SEM), Photoluminescence (PL) and Fourier transform infr...
متن کاملControl capability of electrolytic concentration on refractive index and dielectric constant of porous Silicon layers
Porous Silicon (PS) samples have been prepared by electrochemical anodization of p-type silicon wafer by varying HF concentrations in the electrolytic solution. The structural, surface morphological, optical and surface composition analysis of the prepared samples were done by X-ray diffraction (XRD), Scanning electron microscopy (SEM), Photoluminescence (PL) and Fourier transform infr...
متن کاملRefractive index profiles of Ge-doped optical fibers with nanometer spatial resolution using atomic force microscopy.
We show a quantitative connection between Refractive Index Profiles (RIP) and measurements made by an Atomic Force Microscope (AFM). Germanium doped fibers were chemically etched in hydrofluoric acid solution (HF) and the wet etching characteristics of germanium were studied using an AFM. The AFM profiles were compared to both a concentration profile of the preform determined using a Scanning E...
متن کاملPreparation of thin silica films with controlled thickness and tunable refractive index.
Silica films with controlled thickness and refractive index have been formed by the sequential adsorption of a cationic polyelectrolyte and silica sols. The conditions used to prepare the sol were varied, and allowed films with refractive indices as low as 1.16 to be obtained. The sequential adsorption technique allows the thickness of these films to be controlled in increments of 5-10 nm, depe...
متن کاملSynthetic aperture tomographic phase microscopy for 3D imaging of live cells in translational motion.
We present a technique for 3D imaging of live cells in translational motion without need of axial scanning of objective lens. A set of transmitted electric field images of cells at successive points of transverse translation is taken with a focused beam illumination. Based on Hyugens' principle, angular plane waves are synthesized from E-field images of a focused beam. For a set of synthesized ...
متن کامل