Comparison of long and short axis quantification of left ventricular volume parameters by cardiovascular magnetic resonance, with ex-vivo validation

نویسندگان

  • Helene Childs
  • Lucia Ma
  • Michael Ma
  • James Clarke
  • Myra Cocker
  • Jordin Green
  • Oliver Strohm
  • Matthias G Friedrich
چکیده

BACKGROUND The purpose of the study was to compare the accuracy and evaluation time of quantifying left ventricular (LV), left atrial (LA) volume and LV mass using short axis (SAX) and long axis (LAX) methods when using cardiovascular magnetic resonance (CMR). MATERIALS AND METHODS We studied 12 explanted canine hearts and 46 patients referred for CMR (29 male, age 47 ± 18 years) in a clinical 1.5 T CMR system, using standard cine sequences. In standard short axis stacks of various slice thickness values in dogs and 8 mm slice thickness (gap 2 mm) in patients, we measured LV volumes using reference slices in a perpendicular, long axis orientation using certified software. Volumes and mass were also measured in six radial long axis (LAX) views.LV parameters were also assessed for intra- and inter-observer variability. In 24 patients, we also analyzed reproducibility and evaluation time of two very experienced (> 10 years of CMR reading) readers for SAX and LAX. RESULTS In the explanted dog hearts, there was excellent agreement between ex vivo data and LV mass and volume data as measured by all methods for both, LAX (r² = 0.98) and SAX (r² = 0.88 to 0.98). LA volumes, however, were underestimated by 13% using the LAX views. In patients, there was a good correlation between all three assessed methods (r² ≥ 0.95 for all). In experienced clinical readers, left-ventricular volumes and ejection fraction as measured in LAX views showed a better inter-observer reproducibility and a 27% shorter evaluation time. CONCLUSION When compared to an ex vivo standard, both, short axis and long axis techniques are highly accurate for the quantification of left ventricular volumes and mass. In clinical settings, however, the long axis approach may be more reproducible and more time-efficient. Therefore, the rotational long axis approach is a viable alternative for the clinical assessment of cardiac volumes, function and mass.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Correlation between Left and Right Ventricular Ejection Fractions in Patients with Ischemic Heart Disease, Documented by Cardiac Magnetic Resonance Imaging

Introduction: The correlation between right and left ventricular ejection fractions (RVEF and LVEF, respectively) has been studied in only a small number of patients with a marked decrease in RVEF and LVEF. The aim of the present study was to compare LVEF and RVEF in patients with ischemic heart disease. RVEF and LVEF were measured by Cardiovascular Magnetic Resonance (CMR) imaging. Materials a...

متن کامل

Reproducibility of short axis slice locations in longitudinal cardiovascular magnetic resonance (CMR) studies

Background Longitudinal dynamic changes of myocardial ischemic injury determine left ventricular (LV) remodelling. Using conventional clinical cardiovascular magnetic resonance (CMR) imaging, the registration of short axis (SA) images for comparison of imaging findings at different time points is aided by the application of the same protocol to consistently identify the atrio-ventricular (AV) g...

متن کامل

Heart-Model-Based Automated Method for Left Ventricular Measurements in Cardiac MR: Comparison with Manual and Semi-automated Methods

The accurate measurement of left ventricular (LV) volume and LV mass is important for risk stratification and clinical management, because these parameters are powerful predictors of prognosis related with a variety of cardiovascular disease (1-3). Cardiac magnetic resonance (CMR) imaging performed using the cine gradient-echo and steady state free precession (SSFP) is the reference standard in...

متن کامل

Single and biplane TrueFISP cardiovascular magnetic resonance for rapid evaluation of left ventricular volumes and ejection fraction.

INTRODUCTION Cardiovascular magnetic resonance (CMR) allows very accurate, but time-consuming, volume assessment by the short-axis slice summation technique. The single and biplane methods of volume assessment are used less, partly because FLASH cine imaging provides poor blood-myocardium contrast in long-axis views. TrueFISP gives excellent blood-myocardium contrast, even in patients with hear...

متن کامل

Evaluation of left ventricular volumes and ejection fraction using fast steady-state cine MR imaging: comparison with left ventricular angiography.

Previous studies demonstrated that magnetic resonance (MR) imaging consistently underestimated angiographic measurements of left ventricular (LV) volumes. The purpose of this study was to determine whether MR imaging with steady-state free precession acquisition (SSFP) can provide improved accuracy and reproducibility in measuring cardiac function in comparison with fast spoiled gradient echo c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2011