Efficacy of high-energy collimator for sentinel node lymphoscintigraphy of early breast cancer patients

نویسندگان

  • Kamran Aryana
  • Mohaddeseh Gholizadeh
  • Mehdi Momennezhad
  • Maryam Naji
  • Mohsen Aliakbarian
  • Mohammad Naser Forghani
  • Ramin Sadeghi
چکیده

INTRODUCTION Lymphoscintigraphy is an important part of sentinel node mapping in breast cancer patients. Sometimes star shaped artefacts due to septal penetration can be problematic during imaging. In the current study, we evaluated the possibility of high energy (HE) collimators use for lymphoscintigraphy. PATIENTS AND METHODS Twenty patients with early breast carcinoma were included. Thirty minutes after radiotracer injection (99mTc-antimony sulphide colloid), anterior and lateral images were acquired using a dual head gamma camera equipped with a parallel hole low energy high resolution (LEHR) collimator on one head and HE collimator on another head. All images were reviewed by two nuclear medicine specialists regarding detectability and number of axillary sentinel nodes and presence of star artefact. RESULTS All images taken by LEHR collimators showed star artefact of the injection site. No image taken by HE collimator showed this effect. In two patients the sentinel node was visible only by HE collimator. Tumour location in both of these patients was in the upper lateral quadrant and both had history of excisional biopsy. In two patients additional sentinel node was visible adjacent to the first one only on the LEHR images. CONCLUSIONS HE collimators can be used for sentinel lymph node mapping and lymphoscintigraphy of the breast cancer patients. This collimator can almost eliminate star-shaped artefacts due to septal penetration which can be advantageous in some cases. However, to separate two adjacent sentinel nodes from each other LEHR collimators perform better.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sentinel node mapping for early breast cancer patients using 99mTc-phytate: Single center experience on 165 patients

Introduction: Several radiotracers are being used for sentinel node mapping in patients with breast cancer. In the current study, we reported our experience with 99m-Tc Phytate for sentinel node mapping in Mashhad University of Medical Sciences. Methods: All breast cancer patients who underwent sentinel node mapping using 99m-Tc Phytate were included. All patients received intradermal peri-are...

متن کامل

Dynamic lymphoscintigraphy in breast cancer patients: feasibility and added value

Introduction: Lymphoscintigraphy is imaging of the lymphatic system and has been integrated into the sentinel node mapping procedures. Lymphoscintigraphy usually encompasses early or delayed static images. However, immediate dynamic imaging of the lymphatic basins and tumors has also been used as an adjunct lymphoscintigraphy imaging. The aim of this study was ...

متن کامل

Time frame of sentinel node visualization in early breast cancer patients using intradermal injection of Tc-99m phytate: Imaging beyond 45 minutes does not yield more information

Introduction: One of the major problems of lymphoscintigraphy is the time of patient presence in the nuclear medicine wards. The operating room schedule can be compromised if the patients stay longer than usual in the nuclear medicine departments. However, too early imaging can be falsely negative for sentinel node visualization and delayed imaging may be required. The aim of t...

متن کامل

Radiotracer re-injection in case of sentinel node non-visualization in a breast cancer patient

We reported a 35 year old breast cancer patient who was referred to our nuclear medicine department for sentinel node mapping. She was planned to undergo mastectomy and lymphatic mapping. A dose of Tc-99m Phytate was injection in the peri-areolar region in an intra-dermal fashion. Two hours post-injection no sentinel node was visible in the axilla. Due to a high liver uptake, inadvertent intra-...

متن کامل

Sentinel node detection failure due to defective labeling and large particle size of Tc-99m antimony sulfide colloid

  Introduction: Many radiotracers have been used for sentinel node mapping with acceptable results. The main difference between these radiotracers is the particle size. In the current study, we reported defective labeling of Tc-99m antimony sulfide colloid which resulted in large particle size. Methods: Tc-99m-Antimony sulfide colloid was used for axillary sentinel n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 46  شماره 

صفحات  -

تاریخ انتشار 2012