Feature-based characterization of motion-contaminated calcified plaques in cardiac multidetector CT.

نویسندگان

  • Martin King
  • Maryellen L Giger
  • Kenji Suzuki
  • Xiaochuan Pan
چکیده

In coronary calcium scoring, motion artifacts affecting calcified plaques are commonly characterized using descriptive terms, which incorporate an element of subjectivity in their interpretations. Quantitative indices may improve the objective characterization of these motion artifacts. In this paper, an automated method for generating 12 quantitative indices, i.e., features that characterize the motion artifacts affecting calcified plaques, is presented. This method consists of using the rapid phase-correlated region-of-interest (ROI) tracking algorithm for reconstructing ROI images of calcified plaques automatically from the projection data obtained during a cardiac scan, and applying methods for extracting features from these images. The 12 features include two dynamic, six morphological, and four intensity-based features. The two dynamic features are three-dimensional (3D) velocity and 3D acceleration. The six morphological features include edge-based volume, threshold-based volume, sphericity, irregularity, average margin gradient, and variance of margin gradient. The four intensity-based features are maximum intensity, mean intensity, minimum intensity, and standard deviation of intensity. The 12 features were extracted from 54 reconstructed sets of simulated four-dimensional images from the dynamic NCAT phantom involving six calcified plaques under nine heart rate/multi-sector gating combinations. In order to determine how well the 12 features correlated with a plaque motion index, which was derived from the trajectory of the plaque, partial correlation coefficients adjusted for heart rate, number of gated sectors, and mean feature values of the six plaques were calculated for all 12 features. Features exhibiting stronger correlations ([r] epsilon [0.60,1.00]) with the motion index were 3D velocity, maximum intensity, and standard deviation of intensity. Features demonstrating stronger correlations ([r] epsilon [0.60, 1.00]) with other features mostly involved intensity-based features. Edge-based volume/irregularity and average margin gradient/variance of margin gradient were the only two feature pairs out of 12 with stronger correlations that did not involve intensity-based features. Automatically extracted features of the motion artifacts affecting calcified plaques in cardiac computed tomography images potentially can be used to develop models for predicting image assessability with respect to motion artifacts.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computerized assessment of motion-contaminated calcified plaques in cardiac multidetector CT.

An automated method for evaluating the image quality of calcified plaques with respect to motion artifacts in noncontrast-enhanced cardiac computed tomography (CT) images is introduced. This method involves using linear regression (LR) and artificial neural network (ANN) regression models for predicting two patient-specific, region-of-interest-specific, reconstruction-specific and temporal phas...

متن کامل

Calcium concentration of individual coronary calcified plaques as measured by multidetector row computed tomography.

BACKGROUND Characteristics of individual calcified plaques, especially calcium concentration (CC), may provide incremental value to global calcium scores in the assessment of plaque burden and risk of coronary events and evaluation of therapeutic intervention. In this study, therefore, we assessed the characteristics of individual calcified plaques and their relationship to other parameters der...

متن کامل

Non-invasive detection and assessment of coronary artery disease with multidetector-row computed tomography.

The fast volume coverage of retrospective ECG-gated multidetector-row helical CT(MDCT)arrows for acquisition of the entire heart volume with nearly isotropic spatial resolution(0.5×0.5×0.6 mm)within a single breath-hold. The sub-millimeter spatial resolution enables depiction of the major and also of peripheral coronary artery segments with lumen diameter down to 1 mm. The results of studies of...

متن کامل

Window settings for the study of calcified carotid plaques with multidetector CT angiography.

SUMMARY CT angiography (CTA) shows high sensitivity in detecting calcified plaques, but sometimes a bias in the exact quantification of stenosis degree occurs, mainly caused by the high linear attenuation coefficient of the calcified plaques. The purpose of this technical study was to evaluate the most appropriate CT window parameters for the assessment of calcified plaques stating which of the...

متن کامل

Noninvasive assessment of the carotid and cerebrovascular atherosclerotic plaques by multidetector CT in type-2 diabetes mellitus patients with transient ischemic attack or stroke

BACKGROUND The cerebrovasuclar artery disease as a common complication of type-2 diabetes mellitus (T2DM) caused huge economic burden and lives threatening to patients. We evaluated the prevalence and morphology of carotid and cerebrovascular atherosclerotic plaques in T2DM patients with transient ischemic attack (TIA) or stroke using multidetector CT (MDCT). METHODS 64-MDCT and dual-source C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 34 12  شماره 

صفحات  -

تاریخ انتشار 2007